00191413-01 - 第514页
16 MaDaMaS User Manu al Line Computer UNIX 16.2 MaDaMaS Evaluation User Interface Software Version 501.xx 01/99 Issue 16 - 18 16.2.7.1 "Track Trend" Evaluation The "Track trend" ty pe of eval uation a…

User Manual Line Computer UNIX 16 MaDaMaS
Software Version 501.xx 01/99 Issue 16.2 MaDaMaS Evaluation User Interface
16 - 17
Fig. 16.2.2 Evaluation user interface - "Pick-up reliability" evaluation for all stations
NOTE
If more stations exist than can be displayed in the view area, a scroll bar appears above the info line per-
mitting the display area to be scrolled.
- Exiting from the "Pick-up reliability" evaluation
● Click on the icon.
The "Overall view" evaluation is redisplayed.
bar for
vacuum errors
bar for
identity errors
bar representing
placed components
call-up of the
"Track trend"
and
call-up of
"Track information"
evaluation
evaluation
number / % of
placed components,
identity and vacuum errors

16 MaDaMaS User Manual Line Computer UNIX
16.2 MaDaMaS Evaluation User Interface Software Version 501.xx 01/99 Issue
16 - 18
16.2.7.1 "Track Trend" Evaluation
The "Track trend" type of evaluation allows the eight tracks with the highest identity and vacuum error rates to
be displayed for each station. In the view area the encountered vacuum and identity errors are displayed in
absolute values (text portion) as well as relative (bar chart) to the total number of components placed.
The "Track trend" evaluation is called up from the "Pick-up reliability" chart. This is only possible for placement
stations.
- Calling up the "Track trend" evaluation for all stations
● In the Overall View click on the icon in the "Pick-up reliability" chart.
The track trend evaluation is displayed for all stations.
NOTE
By scrolling the view area using the vertical scroll bar the track trend evaluation can be displayed for
every individual station.
- Calling up the "Track trend" for the individual stations
● Click on the icon in the "Pick-up reliability" evaluation of the diagram of the desired station
(see Fig. 16.2.2).
The track trend evaluation for the selected station is opened (see Fig. 16.2.3).
Fig. 16.2.3 Evaluation user interface - "Track trend" evaluation for a station
number of
components placed,
identity and vacuum errors

User Manual Line Computer UNIX 16 MaDaMaS
Software Version 501.xx 01/99 Issue 16.2 MaDaMaS Evaluation User Interface
16 - 19
NOTE
If more stations exist than can be displayed in the view area, a scroll bar appears above the info line per-
mitting the display area to be scrolled.
- Exiting from the "Track trend" evaluation
● Click on the icon.
The "Pick-up reliability" or "Overall view" evaluation is redisplayed.
16.2.7.2 "Track information" Evaluation
The "Track information" evaluation provides detailed information about the malfunctions that occurred as a
result of vacuum and identity errors on the individual tracks. The precise allocation of the tracks as well as the
vacuum and identity errors encountered are displayed in absolute values (table) as well as relative (bar chart)
to the total number of components placed.
The "Track information" evaluation is called up from the "Pick-up reliability" chart. It is only available for
placement stations.
- Calling up the "Track information" evaluation for a station
● Click on the green bar in the "Pick-up reliability" chart of the desired station (see Fig. 16.2.2).
The track information evaluation for the selected station is displayed (see Fig. 16.2.4).
Fig. 16.2.4 Evaluation user interface -
"
Track information" evaluation for a station