2.11.1.1 Placement System Switched off at the Main Switch, But Still Connected ...
WARNING
The following components still carry potentially lethal voltages even if the main power switch is
switched off:
Cable connection terminals L1, L2, and L3 of the Q1 main power switch (see fig. 2.11 - 4
)
Service socket X102 (see fig. 2.11 - 4
)
Automatic circuit breaker F1 for the service socket (see fig. 2.11 - 4
)
Z1 line filter (see fig. 2.11 - 5
)
Discharge inductor L20 with fuses F21, F22 and F23 (see fig. 2.11 - 5
)
Terminal block X100 for connection of main power supply cable (see fig. 2.11 - 5
)
The color of all individual wires, which still carry potentially lethal voltages even if the main
power switch is switched off, is brown.
Axis unit
2 Operational Safety User Manual SIPLACE CA
2.11 Energy State after Switching Off at the Main Switch Edition 08/2011 EN
108
2
Fig. 2.11 - 4 Power supply unit, front view
Q1 Main power switch
X102 Service socket
F1 Fuse for the service socket
User Manual SIPLACE CA 2 Operational Safety
Edition 08/2011 EN 2.11 Energy State after Switching Off at the Main Switch
109
2
Fig. 2.11 - 5 Power supply unit, back view
X100 Cable connection terminal for the power supply cable
L20 Discharge reactor with fuses F21, F22 and F23
Z1 Line filter