00195941-03-UM SiplaceCA-EN - 第307页

User Manual SIPLACE CA 4 Setting Up and Commissioning Edition 08/2011 EN 4.5 Setting Up the Placement Machine 307 4.5.12.3 Computer Unit of the CA4 and CA3 - Plug In Connectors at the Rear 4 4 4.5.12.4 Fitting the Comput…

100%1 / 508
4 Setting Up and Commissioning User Manual SIPLACE CA
4.5 Setting Up the Placement Machine Edition 08/2011 EN
306
4.5.12.2 Computer Unit of the CA4 and CA3- Plug In Connectors at the Front
4
Also check the following plug-in connectors:
4
Computer unit, front
(fig. 4.5 - 21
)
Plug
Connection cable NOTE
Plug Cable
X0pr
a
X0pr 03009778 Insert as far as the stop
X1pr
a
X1pr 03009838 Insert as far as the stop
X2pr
a
X2pr 03009755 Insert as far as the stop
X3pr
a
X3pr 03009756 Insert as far as the stop
X8pc X8pc 03002970 Secure with screws
X7pc X7pc 03002967 Secure with screws
X5pc X5pc 03002958 + 03002959 Insert as far as the stop
X7pn X7pn 03010055 Secure with screws
X0ps
a
X0ps 03009798 Insert as far as the stop
X1ps
a
X1ps 03009818 Insert as far as the stop
X2ps
a
X2ps 03009757 Insert as far as the stop
X3ps
a
X3ps 03009758 Insert as far as the stop
a) This plug is intended for cameras.
Computer unit,
front
(fig. 4.5 - 21
)
Plug
Connection cable Computer unit, front
(fig. 4.5 - 21
)
Plug
Plug Cable Plug
X1pe X1pe 03010623 X11pt X11pt
a
X3pe X3pe 03010623 X11pc X11pc
X4pe X4pe 03010623 X11pa X11pa
X1pv X1pv 03010615 X4pa X4pa
X2pv X2pv 03010615 X4pc X4pc
X3pv X3pv 03010619 X4pt X4pt
a
a) Only if vision processor option is installed
User Manual SIPLACE CA 4 Setting Up and Commissioning
Edition 08/2011 EN 4.5 Setting Up the Placement Machine
307
4.5.12.3 Computer Unit of the CA4 and CA3- Plug In Connectors at the Rear
4
4
4.5.12.4 Fitting the Computer Unit
Connect the plug-in connectors at the rear of the computer unit (see section 4.5.12.3).
Carefully lift the computer unit onto the rail in the extension kit.
Make sure that you do not squash any cables.
Check that the cables to the front are run in the cable guide plate at the side
(item 1 in fig. 4.5 - 21
, page 304).
Push the computer unit into the extension kit as far as the stop.
Connect the fan cable to the computer unit cable.
Connect the plug-in connectors at the front of the computer unit (see section 4.5.12.2).
Fix the cables to the front panel with cable ties.
Secure the computer unit with the fillister head screw.
Fasten the ground cable to the door (item 2 in fig. 4.5 - 15, page 293), as shown in fig. 4.5 -
17 on page 297.
Lock the doors.
NOTE 4
In case of CA4- and CA3 machine please continue with paragraph 4.5.13
"Install Axis Slide In at
the CA4 and CA3" on page 309.
Computer unit, rear
(fig. 4.5 - 22
)
plugs
Connection cable NOTE
Plug Cable
PE1 Cable ring Grounding cable
Fasten as in fig. 4.5 - 17
, page
297
X27pz X27pz 03003437 W1-W2 Insert as far as the stop
X2pz X2pz 03002966 W1-W5 Fix with screws
X1pz X1pz 03002969 W1-W5 Fix with screws
X62pz X62pz 03002488 Snap into place
PE2 Cable lug Grounding cable Insert as far as the stop
P24 / GND X1 Fan in extension kit Insert as far as the stop
4 Setting Up and Commissioning User Manual SIPLACE CA
4.5 Setting Up the Placement Machine Edition 08/2011 EN
308
4.5.12.5 Fitting the Side Plates
Fasten the ground cable to each side plate (item 6 in fig. 4.5 - 15, page 293), as shown in fig.
4.5 - 17
, page 297.
Fix the side plate to the machine frame with 6 fillister head screws.
Continue with section 4.5.14 "Fitting the Main Fault Indicator", page 311.