User Manual SIPLACE CA 5 Tasks on the Machine Edition 08/2011 EN 5.2 T asks on the SWS 339  Open the protective cover above th e SWS.  Open the bayonet lock at the centering un it and take the ne edle kit out. 5 Fig. 5…

100%1 / 508
5 Tasks on the Machine User Manual SIPLACE CA
5.2 Tasks on the SWS Edition 08/2011 EN
338
5.2.5 Configuring the Needles of the Ejection System
In the SWS GUI switch to the Manual operations -> Wafer handling view and click the Go
to change position button.
The wafer table is removed.
Switch to the Service -> Galil I/O view and activate the D007 Cylinder DE UP/Down option,
to move the die ejector upwards.
Or
In the SWS GUI switch to the Manual operations -> Die handling view and select the Die
eject system tab.
5
5
Click the button.
The wafer table is removed, the die ejector is moved upwards can be accessed.
5
Switch off the placement machine and the SWS properly.
CAUTION 5
Do not move the wafer table by hand, while the die ejector is in an upward position there is dan-
ger of damage by collision with the wafer table!
User Manual SIPLACE CA 5 Tasks on the Machine
Edition 08/2011 EN 5.2 Tasks on the SWS
339
Open the protective cover above the SWS.
Open the bayonet lock at the centering unit and take the needle kit out.
5
Fig. 5.2 - 2 Needle kit with vacuum cap removed
Legend
5
Remove the vacuum cap from the needle kit (1).
Loosen the grub screw (2).
Insert the appropriate needle matrix for your product.
Insert all needles carefully into the segments and align the needles in about the same line.
Loosely screw in the grub screws. The needles still have to be movable.
Carry out the following adjustments with the relevant calibration standard.
(1) Vacuum cap (2) Grub screw
1
2
5 Tasks on the Machine User Manual SIPLACE CA
5.2 Tasks on the SWS Edition 08/2011 EN
340
5.2.5.1 Adjust Needles with Calibration Standard 03080191-xx
Equipment
Needles as spare parts
Calibration standard for the die-ejector (03080191-xx)
With the help of the calibration standard for the die ejector all needles are adjusted into
a defined height and common level. 5
5
Fig. 5.2 - 3 Calibration standard for die-ejector - Item number 03080191-xx