00195941-03-UM SiplaceCA-EN - 第37页
User Manual SIPLACE CA 2 Operational Safety Edition 08/2011 EN 2.1 Safety Instructions 37 WA R N I N G 2 The system is electrically driven. When electrical devices are in use, cert ain part s carry dangerous voltage leve…

2 Operational Safety User Manual SIPLACE CA
2.1 Safety Instructions Edition 08/2011 EN
36
If there is no sufficiently trained personel available in your company for necessary interven-
tions, you should absolutely commission a service technician of ASM Assembly Systems
GmbH & Co.KG! Claims of any kind caused by improper operation or consequential damages
will be refused by the ASM Assembly Systems GmbH & Co.KG!
If particularly hazardous situations are identified while the machine is in use, the machine
owner must immediately notify the manufacturer in writing so that appropriate action can be
taken to reduce the potential danger.
WARNING
In spite of all the safety precautions taken by the manufacturer, failure to use the system as pre-
scribed can result in severe physical injury (e.g. from the moving gantry or lifting table) and/or
considerable damage to equipment. For the machine to be safe, it must be used correctly by
qualified personnel and all warnings must be observed. Some work on the machine (e.g. setting
up) requires training that goes beyond the scope of this Manual. 2
2.1.5.2 Safety of Operators and Other Persons
Machine operators must only carry out work for which they have been adequately trained and
with which they are totally familiar.
NEVER open one of the protective covers if you are not totally familiar with the use and func-
tioning of the machine! Do not open the protective covers during operation unless you are told
to do so in this Manual or in the station software dialog.
NEVER place your head or arms in the gantry and lifting table traveling range while the station
is switched on!
For your own safety, wear work clothes that conform to the guidelines of the professional as-
sociation, i.e. no wide sleeves etc.
Reduce the risks by not wearing scarves, chains or ties at your work post.
People with long hair must wear a protective head covering.

User Manual SIPLACE CA 2 Operational Safety
Edition 08/2011 EN 2.1 Safety Instructions
37
WARNING 2
The system is electrically driven. When electrical devices are in use, certain parts carry dangerous
voltage levels.
Switch off at the main switch and disconnect the placement system from the power supply
before carrying out any work on live components.
Lock the machine as described in section 2.12, page 111.
There is a risk of death, severe injury and/or considerable damage to equipment if these instruc-
tions are not followed.
2.1.5.3 Safety of Plant and Equipment
Never make changes, however minor, unless you are totally aware of the effect they will have
on the overall functioning of the system.
The stations must always be set up, retooled and maintained by appropriately trained person-
nel.
Use only original spare parts and accessories authorized by the ASM Assembly Systems
GmbH & Co.KG. The use of other parts will affect safety and will invalidate the liability for any
consequential damage.
Do not make modifications to the safety equipment. In particular, NEVER deactivate circuit-
breakers or remove safety devices.
2.1.6 Safety Instructions for Laser Units
Permission to operate components that are classified as lasers is withdrawn if
– mechanical damage to the unit is observed, or
– any work is done on the mechanical or electrical parts of the unit. Even damaged or miss-
ing screw locking paint on laser components (e.g. cover plates, fasteners, adjusting po-
tentiometer) counts as work.
– Only service technicians of the operating company trained by the ASM Assembly Sys-
tems GmbH & Co.KG or ASM may change laser compnents.
– Repairs at the laser sub assemblies are only carried out in the factory at ASM.

2 Operational Safety User Manual SIPLACE CA
2.1 Safety Instructions Edition 08/2011 EN
38
2.1.7 Safety Instructions on Permanent Magnets
Powerful permanent magnets are used for the linear motors of the X and Y axes.
DANGER OF DEATH
POWERFUL PERMANENT magnetic track FIELDS INSIDE THE MACHINE 2
The life of persons with passive or active implants such as pacemakers, defibrillators, insulin
pumps etc. is put at risk inside the machine if protective covers are opened.
At-risk people must not stand in the immediate vicinity of the machine.
WARNING
DANGER OF CRUSHING 2
There is a danger of crushing for persons with passive metal implants (e.g. plates, screws).
Never reach into the machine when the protective covers are open and do not bend over the
open machine.
Do not bring any metal objects into the danger area.
CAUTION
POWERFUL PERMANENT MAGNETIC FIELDS 2
There is a risk that the powerful magnetic fields could corrupt data on data media or credit cards
and check cards.