00195941-03-UM SiplaceCA-EN - 第457页
User Manual SIPLACE CA 7 Station Enlargements Edition 08/2011 EN 7.1 Nozzle Changer 457 7.1.4.9 Nozzle Changer "Row 2" for the 6 Segment Col lect&Place CA Head [001 19664-xx] Nozzle changer 2 HF/X/CA/D3, 6 …

7 Station Enlargements User Manual SIPLACE CA
7.1 Nozzle Changer Edition 08/2011 EN
456
7.1.4.8 Position Detection
Every magazine of the nozzle changer has a positioning fiducial for position detection.
7
Fig. 7.1 - 25 Nozzle changer - Position detection
(1) Position fiducial
(2) Position of the nozzles in the magazine in relation to the position fiducial

User Manual SIPLACE CA 7 Station Enlargements
Edition 08/2011 EN 7.1 Nozzle Changer
457
7.1.4.9 Nozzle Changer "Row 2" for the 6 Segment Collect&Place CA Head
[00119664-xx] Nozzle changer 2 HF/X/CA/D3, 6 segment Collect&Place head
The "row 2" nozzle changer may be installed at the following locations:
CA4 machine: locations 1, 2, 3 and 4 (see fig. 7.1 - 20
, page 449)
CA3 machine: Locations 1, , 3 and 4 (see fig. 7.1 - 21
, page 450)
The retrofit package contains apart from the the nozzle changer an assembly kit.
7
Fig. 7.1 - 26 Assembly kit for the nozzle changer "Row 2"
(1) Assembly kit for the nozzle changer "Row 2"

7 Station Enlargements User Manual SIPLACE CA
7.1 Nozzle Changer Edition 08/2011 EN
458
7.1.5 Nozzle Changer for the SIPLACE TwinHead
[03005191-xx] Magazine for 2 nozzles
[03001807-xx] Magazine for 1 nozzle
This nozzle changer can hold up to 12 nozzle magazines. There are 2 magazines available: stan-
dard magazines for special nozzles or grippers. The magazines are seated on a common support.
They are centered with two parallel pins and fixed in place with two countersunk screws.
7
Fig. 7.1 - 27 Nozzle changer for the SIPLACE TwinHead
WARNING 7
Only install the associated nozzle changer for each placement head. There is a risk of head
crashes with mixed configurations.