481
Electromagnetic EN 50081-1 and
compatibility (EMC)EN 61000-6-2
Vibration 2 g / 20 ... 500 Hz
Mechanical shock 15 g / 6 ms
Weight of sensor approx. 0.5 kg
Weight of controller 1 kg
7.13.3 Safety Instructions
7.13.3.1 Safety Instructions for the Sensor of the Coplanarity Module
The sensor works with a semiconductor laser of wave length 670 nm (visible/red).
The maximum optical output power is 1 mW.
The sensor is classified as laser class 2.
When operating the sensor, always follow the relevant regulations of VDE 0837 concerning
"Radiation safety for laser equipment" and German accident prevention regulation entitled
"Laser radiation" (BGV B2).
Also follow the accident prevention regulations applicable in your country.
The following information plates are attached to the front and back of the sensor housing:
7
Fig. 7.13 - 2 Identification of laser class 2 for the sensor
The laser function is shown by an LED (see section 7.13.4).
NEVER look directly into the laser beam, despite the low laser output. The beam is visible, so the
eyes will be protected by the natural eyelid-closing reflex.
7 Station Enlargements User Manual SIPLACE CA
7.13 Coplanarity Laser Module Edition 08/2011 EN
482
WARNING 7
Only authorized personnel may open the housing of the optical sensor.
For repair and service purposes the sensors must always be sent to ASM Assembly Systems
GmbH & Co.KG.
7.13.3.2 Identify Machine with Warning Label W216
7
Warning label W216 "Laser class 2" on the cover next to the main switch,
[03010316-01] (number per machine: 1)
NOTE 7
When the coplanarity laser module is fitted, the placement machine must be classified as laser
class 2. The laser module is not integrated into the EMERGENCY STOP circuit.
Mark the machine with the warning label W216 "Laser class 2" [03010316-xx].
Attach the warning label W216 to the cover, next to the main switch (see item W216 in fig.
7.13 - 3
.
7
7
7
7
7
7
LASER RADIATION!
Do not look into beam
Laser Class 2
User Manual SIPLACE CA 7 Station Enlargements
Edition 08/2011 EN 7.13 Coplanarity Laser Module
483
7
Fig. 7.13 - 3 Warning label W216 beside the main switch
7.13.4 LED Displays on the Controller
The statuses of the coplanarity module are indicated by LEDs. The LED is located on the under-
side of the controller (see item 6 in fig. 7.13 - 4
).
LED state Status display
Green Test object in measuring range
Yellow Measuring range center
Red
Outside the measuring range,
with low reflection
LED Off Laser switched off
LED Power Status display
LED lights up Supply voltage present
LED avg avg1 avg2
Off Off No averaging
Red Off Averaging 1
Off Red Averaging 2
Red Red Averaging 3