Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis 05/2005 Edition 71 2.7 Final t asks : Reverse the above sequence to fit, and do th e same for all panels, doors and earth bonding. 2 : Dock the MT C…

100%1 / 74
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
70
: Measure the distance between the pinion and the motor in order to be able to set the new pin-
ion to the same distance.
: Loosen the six screws on the clamping ring and remove the motor pinion.
: Attach the new pinion.
: Insert the new thrust sleeve and tighten the six screws.
: Check whether the pinion is at the same distance from the motor as the old pinion.
2
: Remove the belt tension sensors from the old supports and screw them onto the new supports.
2
2
2
2
2
2
2
2
2
2
Belt tension sensors
Old support
New support
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition
71
2.7 Final tasks
: Reverse the above sequence to fit, and do the same for all panels, doors and earth bonding.
2
: Dock the MTC2 into the placement machine again.
: Connect it to the power supply.
2
2
2
2
Service Manual: Replacement of ball screw for SIPLACE MTC2 lifting axis
05/2005 Edition