3OM-1011-001 - 第150页
(Cause 1) Check whether or not solenoid valves (YSV01A) and (YSV01B) for Y A-axis stationary position stopper forward and backward movement are working normally . (Reset Procedure in the case of Cause 1) Reset Procedure …

Error Code Display A Display B
0305-001 2-104 Tg0859-PM-ER
3. Trouble Shooting after Error Display
60 04 08 INTERLOCK NOZZLE WAS NOT SEATED PROPERLY IN NOZZLE
STOCKER (B2).
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
60 04 07 INTERLOCK NOZZLE WAS NOT SEATED PROPERLY IN NOZZLE
STOCKER (B1).
60 04 06 INTERLOCK
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
NOZZLE WAS NOT SEATED PROPERLY IN NOZZLE
STOCKER (A2).
60 04 05 INTERLOCK NOZZLE WAS NOT SEATED PROPERLY IN NOZZLE
STOCKER (A1).
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.

(Cause 1) Check whether or not solenoid valves (YSV01A) and (YSV01B) for YA-axis stationary
position stopper forward and backward movement are working normally.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not YA-axis stationary position stopper forward sensor (BPH029) is
functioning correctly.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
0305-001 2-105 Tg0859-PM-ER
3. Trouble Shooting after Error Display
Error Code Display A Display B
60 04 0C INTERLOCK YA AXIS POSITIONING BACKWARD WAS NOT
DETECTED.;BPH029
60 04 0B INTERLOCK YA AXIS POSITIONING FORWARD WAS NOT
DETECTED.;BPH028
(Cause 1) Check whether or not solenoid valves (YSV01A) and (YSV01B) for YA-axis stationary
position stopper forward and backward movement are working normally.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not YA-axis stationary position stopper forward sensor (BPH028) is
functioning correctly.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
60 04 0A INTERLOCK P.C.B. POSITIONING ERROR WAS DETECTED.
;BPH150 E / NR
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
60 04 09 INTERLOCK BEAM-A UNIT CAME VERY CLOSE TO BEAM-B
UNIT.;BPH027 E / NR
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.

60 05 02 SAFETY CIRCUIT AREA SENSORS FOR BEAM-B SIDE WERE
ACTIVATED.;BPH083,BPH084 E / NR
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
0305-001 2-106 Tg0859-PM-ER
3. Trouble Shooting after Error Display
60 05 01 SAFETY CIRCUIT AREA SENSORS FOR BEAM-A SIDE WERE
ACTIVATED.;BPH081,BPH082 E / NR
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
60 04 0E INTERLOCK YB AXIS POSITIONING BACKWARD WAS NOT
DETECTED.;BPH031
(Cause 1) Check whether or not solenoid valves (YSV02A) and (YSV02B) for YB-axis stationary
position stopper forward and backward movement are working normally.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not YB-axis stationary position stopper forward sensor (BPH031) is
functioning correctly.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
60 04 0D INTERLOCK YB AXIS POSITIONING FORWARD WAS NOT
DETECTED.;BPH030
(Cause 1) Check whether or not solenoid valves (YSV02A) and (YSV02B) for YB-axis stationary
position stopper forward and backward movement are working normally.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not YB-axis stationary position stopper forward sensor (BPH030) is
functioning correctly.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.