3OM-1011-001 - 第234页

3. Control-to-Control Communication Error Code and List of Error Messages 0305-001 4-29 Tg0859-PM-ER Error Code Display A Display B 12000000 A COMMUNICA TION PROCE- DURE ERROR OCCURRED AN IMAGE T AKEN BY THE SPECIFIED CA…

100%1 / 317
3. Control-to-Control Communication Error Code and List of Error Messages
0305-001 4-28 Tg0859-PM-ER
Error Code Display A Display B
11XXXXXX COMMUNICATION DATA
except the ERROR
above-
described
codes
ETC.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
11530000 RECOGNITION ERROR
IMAGE OUTPUT
NOZZLE PROTRUSION PRESENTS ON SOME LEADS.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
3. Control-to-Control Communication Error Code and List of Error Messages
0305-001 4-29 Tg0859-PM-ER
Error Code Display A Display B
12000000 A COMMUNICATION PROCE-
DURE ERROR OCCURRED
AN IMAGE TAKEN BY THE SPECIFIED CAMERA IS NOT
YET RECEIVED.
12000001 A COMMUNICATION PROCE-
DURE ERROR OCCURRED
THE DATA OF THE SPECIFIED NOZZLE IS NOT YET
TRANSFERRED.
12000002 A COMMUNICATION PROCE-
DURE ERROR OCCURRED
THE DATA OF THE SPECIFIED MARK IS NOT YET
TRANSFERRED.
12000003 A COMMUNICATION PROCE-
DURE ERROR OCCURRED
THE DATA OF THE SPECIFIED COMPONENT IS NOT
YET TRANSFERRED.
12XXXXXX A COMMUNICATION PROCE-
except the DURE ERROR OCCURRED
above-
described
codes
ETC.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
15000001 A COMMUNICATION ERROR
OCCURRED IN LIGHTING
CONTROL BOARD
15XXXXXX A COMMUNICATION ERROR
except the OCCURRED IN LIGHTING
above- CONTROL BOARD.
described
codes
AN ERROR OCCURRED DURING DATA TRANSFER BE-
TWEEN RECOGNITION AND LIGHTING CONTROL
BOARDS.
OTHERS
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all axes to their original positions.
(2) Re-start.
(3) If the device can't be re-started, contact our service personnel.
4. Communication Error Code between Lighting
Control Boards and List of Error Messages
Shown are the contents of the error codes which might be issued in the com-
munication processing between the lighting control boards.
0305-001 4-30 Tg0859-PM-ER
4. Communication Error Code between Lighting Control Boards and List of Error Messages