SIPLACE X-Series (SIPLACE X-Series S, from SC 708.1) Edition 05/2015 EN User manual - 第199页
User manual SIPLACE X-Series 3 Technical data and assemblies From software version 708.1 Version 05/2015 3.9 X feeder modules for SIPLACE X-Series 199 3.9.6 Energy and dat a interface (EDIF) for X feeder modules Item no.…

3 Technical data and assemblies User manual SIPLACE X-Series
3.9 X feeder modules for SIPLACE X-Series From software version 708.1 Version 05/2015
198
3.9.5.3 Feeder module adapter for the X-Series with Reject Conveyor
3
Fig. 3.9 - 19 Feeder module adapter for the X-Series with Reject Conveyor
(1) Adapter for X-Series feeder modules (item no. 00141305-xx)
(2) Adapter plate for Reject Conveyor (item no. 00141308-xx)
(3) Reject conveyor (reject module)

User manual SIPLACE X-Series 3 Technical data and assemblies
From software version 708.1 Version 05/2015 3.9 X feeder modules for SIPLACE X-Series
199
3.9.6 Energy and data interface (EDIF) for X feeder modules
Item no. 00141247-xx Energy and data interface for X feeder modules
3
Fig. 3.9 - 20 Energy and data interface for X feeder modules
(1) Unlocking button for locking latch
(2) Operator panel
(3) Data cable
(4) Power supply cable
(5) Electronics housing
(6) Fold-out feet
(7) Omega profile for guiding feeder modules
(8) Locking latch
(9) Locating hole for front centering pin of feeder module
(10) Base plate
(11) Tape reel holder

3 Technical data and assemblies User manual SIPLACE X-Series
3.9 X feeder modules for SIPLACE X-Series From software version 708.1 Version 05/2015
200
3.9.6.1 Description
The energy and data interface allows X feeder modules to be used outside the machine and setup
area. The interface consists of an aluminum frame with omega profile (item 7 in fig. 3.9 - 18
, page
197
) for holding and guiding the feeder modules. As with the X component trolley, the feeder mod-
ule is placed on the omega profile, with the slider guides, and is pushed forwards until the front
centering pin of the feeder module is fully inserted into the locating hole (item 9 in fig. 3.9 - 18
,
page 197
). The locking latch (item 8 in fig. 3.9 - 18, page 197) locks the feeder module in this po-
sition. To remove the feeder module, simply press the release button (item 1 in fig.
3.9 - 18
, page 197 ). The locking latch (item 8 in fig. 3.9 - 18, page 197) is pressed down and re-
leases the feeder module. Fold-out feet (item 6 in fig. 3.9 - 18
, page 197) stabilize the position of
the energy and data interface, particularly for wide feeder modules.
The electronic housing (item 5 in fig. 3.9 - 18
, page 197) holds the electronic control unit for the
energy and data interface. The operator panel (item 2 in fig. 3.9 - 18
, page 197) consists of start
and stop buttons and two status LEDs. Communication with a PC takes place via the data cable
(item 3 in fig. 3.9 - 18
, page 197 ). The power supply cable (item 4 in fig. 3.9 - 18, page 197) is
connected to the power supply unit provided.
3.9.6.2 Usage
The energy and data interface is used to check, maintain and repair X feeder modules. It can also
be used for setting up in advance for PCB production. In this case, the energy and data interface
is fixed to the base plate (item 10 in fig. 3.9 - 20
, page 199). The tape reel holder (item 11 in fig.
3.9 - 20
, page 199) is also mounted on the base plate. When a component tape is inserted, you
can check or reset the increment, pick-up position and conveyor speed. The detailed user manual
describes how to use the interface and the necessary servicing work.
3.9.6.3 Scope of delivery
– Single Slot EDIF
– Power supply, 100 - 120 / 200 - 240 VAC, +30VDC, 4.3 A
– Base plate with tape reel arm
– User manual