SIPLACE X-Series (SIPLACE X-Series S, from SC 708.1) Edition 05/2015 EN User manual - 第268页
5 Working with the machine User manual SIPLACE X-Series 5.2 Controls and displays From software version 708.1 Version 05/2015 268 5.2.3 Ergonomic arrange ment of controls Fig. 5.2 - 1 , page 265 provides an overview of t…

User manual SIPLACE X-Series 5 Working with the machine
From software version 708.1 Version 05/2015 5.2 Controls and displays
267
Keyboard 5
The keyboard is located beneath the monitor.
5
Indicator lamp with horn - two color (standard) 5
The sequence of colors of the indicator lamps is white - green. These lamps are used to signal
operating statuses and malfunctions of the machine. See also Section 5.7 on page 286.
Indicator lamp with horn - three color (optional) 5
The sequence of colors of the indicator lamps is red - yellow - green. These lamps are used to
signal operating statuses and malfunctions of the machine. See also Section 5.7 on page 286.
CAUTION
Risk of collision on the monitor with keyboard
When working on the component trolley, there is risk that you could collide with the mon-
itor and keyboard.
Turn the monitor and keyboard away to the side.
Make sure that you are not under the monitor and keyboard with your head.

5 Working with the machine User manual SIPLACE X-Series
5.2 Controls and displays From software version 708.1 Version 05/2015
268
5.2.3 Ergonomic arrangement of controls
Fig. 5.2 - 1, page 265 provides an overview of the position of the controls. They are subdivided
into the following groups:
Operator panel at location 1 5
– LCD touchscreen
– Keyboard with trackball
– Start button
– Stop button
– Main switch
Operator panel at location 2 5
– LCD touchscreen
– Keyboard with trackball
– Start button
– Stop button
5.2.3.1 Controls on the machine's operator panels
The two operator panel have identical control functions.
Monitor, keyboard, start and stop buttons 5
There is a monitor and a keyboard on both sides of the machine.
The start and stop buttons are located beneath the keyboard. The on-screen dialog will occasion-
ally prompt you to activate certain actions using buttons, and this arrangement will make it easier
for you both to activate and to interactively control these actions.
Main switch 5
The main power switch is part of the power module. It is located here because it is only needed
for servicing and preventive maintenance work and is therefore not subject to frequent use.

User manual SIPLACE X-Series 5 Working with the machine
From software version 708.1 Version 05/2015 5.3 Switching on the SIPLACE line
269
5.3 Switching on the SIPLACE line
5.3.1 Starting the SIPLACE Pro Line Control GUI program
Start the program on the line computer SIPLACE Pro Line Control GUI
via the Windows Start menu
Start --> Programs --> SIPLACE Pro --> LCGUI
or
with the icon on your desktop.
Enter your user data.
The system connects to the SIPLACE Pro server and opens the user interface.
5.3.2 What to consider before switching on the stations
5
Check whether the stations are connected to the power and compressed air supplies.
Perform a sight check of the stations. Make sure that there are no obstacles in the travel
range of the gantries.
Make sure that the Z axes of all heads are in their uppermost end positions.
With waffle pack changer option: Switch the waffle pack changer on before you switch the ma-
chine on.
CAUTION
Before you switch on the stations, please perform the following steps.