User manual SIPLACE X-Series 6 Station extensions From software version 708.1 Version 05/2015 6.1 Nozzle changer 341 6 Fig. 6.1 - 12 Nozzle changer for the C&P20 P- changing the magazine (example of 6 magazines) (1) …

100%1 / 430
6 Station extensions User manual SIPLACE X-Series
6.1 Nozzle changer From software version 708.1 Version 05/2015
340
6.1.3.8 Changing the magazine
Press the lever (item 1 in fig. 6.1 - 12, page 341), to release the magazine from the balls of the
snap fasteners (item 5 in fig. 6.1 - 12
, page 341). Lift the magazine off the base.
6
WARNING
Risk of head crashes with protruding lever
Any lever that is protruding over the magazine (item 1 in fig 6.1 - 12
) can result in a head
crash.
You should therefore make sure that the lever does not protrude over the maga-
zines.
User manual SIPLACE X-Series 6 Station extensions
From software version 708.1 Version 05/2015 6.1 Nozzle changer
341
6
Fig. 6.1 - 12 Nozzle changer for the C&P20 P- changing the magazine (example of 6 magazines)
(1) Lever for raising the magazine
(2) Parallel pin, engages in the hole in the magazine
(3) spring pin for triggering the microswitch
(4) Pin of the slide mechanism, moves the locking plate
(5) Ball of snap fastener
(6) Parallel pin, engages in the slot in the magazine
(7) Locking plate in the "magazine locked" position
6
PLEASE NOTE
Move the locking plate into the "Magazine locked" position.
Before inserting, align the magazine so that the centering pins (items 2 and 6 in fig.
6.1 - 12
, page 341) slide into the centering holes and slot.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
6 Station extensions User manual SIPLACE X-Series
6.1 Nozzle changer From software version 708.1 Version 05/2015
342
Place the magazine on the snap fastener balls (item 5 in fig. 6.1 - 12, page 341).
Press the magazine down evenly so that the snap fastener balls engage in all the snap fas-
teners at the same time.
6.1.3.9 Position detection
Each magazine of the nozzle changer has two fiducials: one for determining the position and one
for determining the angular position.
6
Fig. 6.1 - 13 Nozzle magazine - holder numbering, fiducials for determining the position and angular position
(1) Locking plate in the "magazine open" position
(2) Fiducial for determining the position
(3) Fiducial for determining the angular position