SIPLACE X-Series (SIPLACE X-Series S, from SC 708.1) Edition 05/2015 EN User manual - 第347页
User manual SIPLACE X-Series 6 Station extensions From software version 708.1 Version 05/2015 6.1 Nozzle changer 347 6.1.4.5 T echnical dat a 6 Nozzle changer fo r the SIPLACE M ultiSt ar Number of ma gazines a*a SIPLACE…

6 Station extensions User manual SIPLACE X-Series
6.1 Nozzle changer From software version 708.1 Version 05/2015
346
6.1.4.4 Nozzle magazine for 28xx nozzles
6
Fig. 6.1 - 17 Nozzle magazine for 28xx nozzles
(1) 5 garages for 28xx nozzles with a maximum nozzle length of 12.5 mm
(garage numbers 1, 5, 6, 8 and 9)
(2) 4 garages for 28xx nozzles with a maximum nozzle length of 16.5 mm
(garage numbers 2, 3, , 4 and 7)
(3) Fiducials (only visible when locking plate open)

User manual SIPLACE X-Series 6 Station extensions
From software version 708.1 Version 05/2015 6.1 Nozzle changer
347
6.1.4.5 Technical data
6
Nozzle changer for the SIPLACE MultiStar
Number of magazines
a*a
SIPLACE X2 S/X3 S/X4 S 6
SIPLACE X4i S 6
6
4
Number of nozzle holders
SIPLACE X2 S/X3 S/X4 S 6
SIPLACE X4i S 6
78
48
Standard configuration
SIPLACE X2 S/X3 S/X4 S 6
6
6
SIPLACE X4i S 6
5 magazines with 60 x 20xx nozzle garages
1 magazine with 9 x 28xx nozzle garages
3 magazines with 36 x 20xx nozzle garages
1 magazine with 9 x 28xx nozzle garages
Option: Nozzle changer "row 2" 4 magazines with 48 nozzle garages
Nozzle types 10xx, 11xx, 12xx
20xx, 28xx
*)a With restrictions at location 2 for MTC/WPC

6 Station extensions User manual SIPLACE X-Series
6.1 Nozzle changer From software version 708.1 Version 05/2015
348
6.1.4.6 Configuration example: CPP for SIPLACE X4i S
Locations 1, 2, 3 and 4 can each accommodate one nozzle changer for the CPP head (item 1 in
fig. 6.1 - 18
, page 348).
6
Fig. 6.1 - 18 Position of nozzle changer for the SIPLACE MultiStar machine - configuration example (SIPLACE X4i S)
6
6
(1) Nozzle changer
(2) SIPLACE MultiStar
(3) Stationary cameras
(4) Nozzle changer row 2 (optional)
PLEASE NOTE
Stop machine if magazine missing
The safety circuit stops the machine if magazines are missing or not fitted correctly.
Use all magazine places.
(2)(1)
(1)
(2)
(1)
(2) (2)
(3)
(3)
(1)
(4)
(4)