SIPLACE X-Series (SIPLACE X-Series S, from SC 708.1) Edition 05/2015 EN User manual - 第350页

6 Station extensions User manual SIPLACE X-Series 6.1 Nozzle changer From software version 708.1 Version 05/2015 350 6.1.4.8 Nozzle changer "row 2" for the SIPLACE Multi St ar The "nozzle changer for row 2…

100%1 / 430
User manual SIPLACE X-Series 6 Station extensions
From software version 708.1 Version 05/2015 6.1 Nozzle changer
349
6.1.4.7 Configuration example: CPP for SIPLACE X4 S
Locations 1, 2, 3 and 4 can each accommodate one nozzle changer for the CPP head (item 1 in
fig. 6.1 - 19
, page 349).
6
Fig. 6.1 - 19 Position of nozzle changer for the SIPLACE MultiStar machine - configuration example (SIPLACE X4 S)
6
6
(1) Nozzle changer
(2) SIPLACE MultiStar
(3) Stationary cameras
(4) Nozzle changer row 2 (optional)
PLEASE NOTE
Stop machine if magazine missing
The safety circuit stops the machine if magazines are missing or not fitted correctly.
Use all magazine places.
(2)(1)
(1)
(2)
(1)
(2) (2)
(3)
(3)
(1)
(4)
(4)
6 Station extensions User manual SIPLACE X-Series
6.1 Nozzle changer From software version 708.1 Version 05/2015
350
6.1.4.8 Nozzle changer "row 2" for the SIPLACE MultiStar
The "nozzle changer for row 2" option enables you to configure an additional row of nozzle chang-
ers for the SIPLACE MultiStar.
The retrofit package contains the nozzle changer and an assembly kit.
6.1.4.9 Assembly
The nozzle changers are fixed to the COT insert.
6
Fig. 6.1 - 20 Assembly position of nozzle changer - view from below
(1) Sloping side points towards the COT insert
(2) Vertical side points towards the PCB conveyor
Align the nozzle changer so that the sloping side points towards the COT insert.
6
WARNING
Risk of head crashes with mixed configurations!
There is a risk of head crashes with mixed configurations.
Only install the associated nozzle changer for each placement head, with the nozzle
magazines for the respective placement head.
User manual SIPLACE X-Series 6 Station extensions
From software version 708.1 Version 05/2015 6.1 Nozzle changer
351
6.1.4.10 Notes on operation
When you fill a magazine with a certain nozzle type for the first time, attach an adhesive label
to identify the type.
6
Open the locking plate and place the nozzles in the nozzle holders.
Close the locking plate so that the nozzles cannot drop out of the magazines.
6
6
Programming the nozzle changer is described in the SIPLACE Pro user manual.
6.1.4.11 Changing the magazine
Press the lever (item 1 in fig. 6.1 - 21, page 352), to release the magazine from the balls of the
snap fasteners (item 5 in fig. 6.1 - 21
, page 352). Lift the magazine off the base.
6
PLEASE NOTE
Fill the magazines off the machine and always replace complete magazines.
CAUTION
Filling up magazines!
Before you fill magazines, make sure that all the nozzles on the Collect&Place head
have
been returned to their magazines.
PLEASE NOTE
Risk of jamming!
If components fall onto magazines, there is a risk that the locking plate could jam.
Do not allow components to drop onto the magazines.
You should therefore regularly clean the magazines and free locations.
WARNING
Risk of head crashes with protruding lever
Any lever that is protruding over the magazine (item 1 in fig 6.1 - 21
) can result in a head
crash.
You should therefore make sure that the lever does not protrude over the maga-
zines.