M1series_ServiceManual_e - 第16页

1 Installation 1-8 ⑥ Connect the power cable and ground line i ndependently of other machines whi ch may be a noise source, such as a compressor, welding machine. ⑦ Connect the air supply coupler 65SN or 85SN (Nitto) or …

100%1 / 68
1 Installation
1-7
ACTION:
Locate the machine to the specified place.
Adjust the conveyor height to 900 mm by rotating the adjust feet.
900+/-20mm
or
950+/-20mm(SMEMA)
Place a level on the conveyor and adjust the height so that the machine is level lengthwise and
crosswise.
Level
When the conveyor has become level, check if the height is 900+/-20 mm. Then fix the adjust feet
with nuts.
The head assy. is fixed to the XY shafts with nylon ties. Take them off with nippers.
1 Installation
1-8
Connect the power cable and ground line independently of other machines which may be a noise
source, such as a compressor, welding machine.
Connect the air supply coupler 65SN or 85SN (Nitto) or an alternate to the air coupler on the filter
regulator in the machine. Then, make sure the filter regulator indicates 0.49 MPa (5 kgf/cm
2
).
Filter Regulator
Air Coupler
Air Coupler 65SN or 85SN
1 Installation
1-9
Connecting Loader with Machine
There is an entrance sensor at the entrance of the machine. If the loader is installed upstream of the
machine, the entrance sensor must be moved to avoid interruption with the loader.
After the sensor has been moved, align the conveyors for smooth board transfer.
NOTE: While moving a sensor and aligning conveyors, the power to the machine must be turned off.
a: The sensor position without a loader.
b: The sensor position with a loader installed upstream of the machine.
Position with loader installed
Normal position
Loaders frame
Entrance Sensor
Loader rack