3 Mechanical Section 3-1 3 Mechanical Section

100%1 / 68
2 Periodical Checks
2-6
Stopper
Check for movement and noise.
Make sure there is no components on stopper.
Main Clamp
Check adjust plate for wear and flaw.
Side Clamp
Check for wear and flaw.
Rear Clamp
Check for wear and flaw.
Buffer Stopper
Check for wear and flaw.
ANC Clamp
Check for wear and flaw.
Fixed Camera
Clean filters and lamp case.
Teach Camera
Clean a filter and lamp case.
Scan Camera
Clean a filter and lamp case.
Clean mirror.
Camera Illumination
Check movement and brightness.
Operation Switches
Check if all actuators work properly in the Signal I/O screen.
Check emergency stop switch.
Alarm Beacon
Check if all lamps light.
Make sure it is fixed securely.
Hazard Alarm
Check if alarm sounds.
Warning Alarm
Check if alarm sounds.
Cameras
Execute “VISION TEST” and check result.
Pickup Coordinates
Check feeder banks.
Electrodes on Feeder Bank
Check the condition.
Placement
Make sure components are placed on specified places.
3 Mechanical Section
3-1
3
Mechanical Section
3 Mechanical Section
3-2
Head
Solenoid Valves
NOTE: Do not disassemble the solenoid valves for any purposes. Disassembling them is not covered by the
warranty.
Part No.
Part Name
LG0-M71A1-00X SOLENOID VALVE
Air Passage
Clean the air passage (from the air filter assy. to the nozzle holder) periodically to maintain machine
accuracy and placement rate. Give an air blow either from nozzle holder or from an air tube.
Air Filter
Take out air filter elements from air filter assy., once a week, to check if they are dirty. Replace the elements
if they are clogged with dust.