M1series_ServiceManual_e - 第58页

4 Electrical Section 4-6 Adjustment of Board Detection Sensors ■ Sensors z LG0-M90H3-00X PHOTO SENSOR EX-22A (SUNX) ・ Entrance Sensor ・ Exit Sensor ・ Exit Buffer Arrival Sensor z LG0-M90H1-00X PHOTO SENSOR AMP. PS2-61 (K…

100%1 / 68
4 Electrical Section
4-5
Electrodes on Feeder / Feeder Bank
When electrodes on the feeder bank and the tape feeder get dirty, clean them as follows:
Clean them very lightly to just get rid of the dust with dry cotton swab or nonwoven fabric. Check the pins
for deformation. If you find a bent pin, do not use the feeder as it is. It may result in a flaw on electrodes.
Do not use alcohol, water base detergents and organic solvent, such as
thinner, benzene and acetone.
Do not use sandpaper and tools with sharp blade or edge, such as a knife and
a screwdriver.
NOTE: If they get stubborn stains, try not to get rid of them forcedly. Please contact us.
Cotton swab
Pin Electrodes on feederElectrodes on feeder bank
Cotton swab
4 Electrical Section
4-6
Adjustment of Board Detection Sensors
Sensors
z LG0-M90H3-00X PHOTO SENSOR EX-22A (SUNX)
Entrance Sensor
Exit Sensor
Exit Buffer Arrival Sensor
z LG0-M90H1-00X PHOTO SENSOR AMP. PS2-61 (KEYENCE)
LG0-M90H2-00X PHOTO SENSOR HEAD PS-49 (KEYENCE)
Board Arrival Sensor
Buffer Board Arrival Sensor
Adjustment
z LG0-M90H3-00X PHOTO SENSOR
Place a production board on the conveyor.
Turn the Sensitivity Adjuster fully counterclockwise to the sensitivity minimum position. (The
adjuster turns 3/4 rotation overall. If it is turned clockwise, the sensitivity increases, if turned
counterclockwise, the sensitivity decreases.)
Turn the Sensitivity Adjuster clockwise slowly and confirm the point A where the Orange LED
lights up.
Remove the board and continue to turn Sensitivity Adjuster clockwise and confirm the point B
where the Orange LED lights up. (If the sensor does not light up, just turn the adjuster clockwise to the
end.)
Turn the Sensitivity Adjuster to the center of A and B. Determine the point as a detecting point.
Put back the board on the conveyor. Be sure that the Orange LED and Green LED light up at the same
time. When you remove the board, only the Green LED should light up.
NOTE: If your machine is equipped with the CE safety conveyor cover, make sure to stick the black rubber sheet
(LG0-M9AA1-00 GOM) on the bottom surface of the cover to prevent mis-detection.
Operation Indicator (Orange LED)
(Indicators are located on the back.)
Stability Indicator (Green LED)
Sensitivity Adjuster
MAX
4 Electrical Section
4-7
z LG0-M90H1-00X PHOTO SENSOR AMP.
LG0-M90H2-00X PHOTO SENSOR HEAD
Place a production board on the conveyor.
Find the optimum angle of the Sensor Head.
(1) Loosen two screws of the Sensor Head a little.
(2) Turn the Sensitivity Adjuster fully counterclockwise to the sensitivity minimum position.
(The adjuster turns 3 rotations overall. If it is turned clockwise, the sensitivity increases, if
turned counterclockwise, the sensitivity decreases. The adjuster clicks when it reaches the end
position.)
(3) Turn the Sensitivity Adjuster one rotation clockwise.
(4) Have the sensor detect the board and adjust the angle of the Sensor Head so that the sensor
becomes “Stable operating state” (Red and Green LEDs light up at the same time.). Decide the
angle at the midpoint in the range of the Sensor's “Stable operating state”. Then tighten the
screws.
Turn the Sensitivity Adjuster fully counterclockwise to the sensitivity minimum position.
Have the sensor detect the board and turn the Sensitivity Adjuster clockwise slowly and confirm the
point C where the Red LED lights up.
Turn the Sensitivity Adjuster fully clockwise to the sensitivity maximum position.
Remove the board and move the machine's head assembly over the sensor in all directions. Check if
the Red LED lights up. If the Red LED lights up, turn the Sensitivity Adjuster counterclockwise and
find the point D where the Red LED goes out. If the Red LED does not light up, turn the Sensitivity
Adjuster fully clockwise.
Turn the Sensitivity Adjuster to the center of C and D. Determine the point as a detecting point.
Put back the board on the conveyor. Be sure that the Red and Green LEDs light up. If you remove the
board, both LEDs should go out.
Adjust the angle.
Mounting Screws
Stable Operation Indicator
(
Green LED
)
Operating Indicator
(Red LED)
Board
Operation Mode Switch
(
Fixed at 1
)
Timer Setting Trimmer
(No adjustment needed)
Sensitivity Adjuster
(3-rotation type)
Alarm Switch
(OFF)
Sensor Head Sensor Amplifier