00196433-02_AI_Vakuumpumpe_X-Serie_70XDE+EN.pdf - 第67页

Assembly instructions: Vacuum pump for SIPLACE X-series 04/2009 Edition 67 2 Assembly instructions: V acuum pump for SIPLACE X-series 2.1 Description of the functions A vacuum is neede d for the C&P 2 0 A placement h…

100%1 / 128
Montageanleitung Vakuumpumpe SIPLACE X-Serie
Ausgabe 04/2009
66
Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
67
2 Assembly instructions: Vacuum
pump for SIPLACE X-series
2.1 Description of the functions
A vacuum is needed for the C&P 20 A placement head. In the past, the entire vacuum was gen-
erated by Venturi nozzles in the C&P 20 A placement head. 2
This vacuum pump generates a vacuum more efficiently (than Venturi nozzles) and thus reduces
the power
consumption. In this way it covers the basic vacuum requirement. 2
2
The TwinHead and CPP placement head are not vacuum pump-compatible. The compressed air
supply for the gantry concerned must not be converted to vacuum operation. If this done, the re-
turn cylinder cannot move out and the Z axis thus remains in the top position. 2
2
If a gantry is converted from CP20A to TwinHead or CPP head, the original compressed air supply
must be restored for this gantry. All the modules for this gantry must be refitted.
Partial conversion of the pneumatic unit, for example, can lead to
serious faults in the placement
machine in compressed air operation because the gantry hoses are detached (additional hoses
for vacuum). 2
2
If a gantry with TwinHead or CPP is converted to CP20A with vacuum operation, the vacuum op-
eration must be retrofitted for this gantry.
If a C&P head that has been converted to vacuum oper
ation is used on a gantry with compressed
air, the silicone hoses may become detached from the segments, leading to serious damage to
the head. 2
2
2
Hoses must NOT be bent, not even during unpacking, otherwise they are no longer usable. 2
2
2
Assembly instructions: Vacuum pump for SIPLACE X-series
04/2009 Edition
68
2.2 Requirements
The requirements for assembly are: 2
Machine series from no. B-079 with vacuum-compatible cable and hose carrier:
03022236-xx Cable and hose carrier for SIPLACE X-series 1G
03022237-xx Cable and hose carrier for SIPLACE X-series 2G O
03021065-xx Cable and hose carrier for SIPLACE X-series 2G E
03050655-xx (Spread Spectrum)
03050817-xx (Spread Spectrum)
03050934-xx (Spread Spectrum)
The X-4I can generally be converted.
C&P20 placement head (item no.: 03008827-
03
CP20A placement head (item no.: 03062095-xx)
2
2
The SIPLACE X4I can generally be converted. 2
It is not possible to convert placement machines with serial numbers less than B079. 2
2
2.3 Tools required
Fork wrench, size 10
Set of hexagon socket spanners
Set of Phillips screwdrivers
Set of diagonal cutters
Tubing nippers
Release tool for Q8 (item no. 03047090-xx)
2