SM_SXDX12_intern_03-2017_en - 第36页

Service Work Replacement Y-Guide R ails Fin al Work 36 Service Manual (Internal) SIPLACE SX1/SX2/DX1/DX2 Among them was found a Teflon pr otector. This is to avoid that the magnets will be scratched. Press with the lever…

100%1 / 38
Service Work
Final Work Replacement Y-Guide Rails
Service Manual (Internal) SIPLACE SX1/SX2/DX1/DX2 35
2.7 Replacement Y-Guide Rails
Tools required
1 x 03065307-xx Exccentric device Y-leadership, kpl.
1 x 00376625-xx Torque wrench with reversible ratchet
1 x 03065304-xx spacer for Y magnets
1 x 60519813-xx Gantry lift, SX1/2 CoD
SX1 - 1 x 60519814-xx gantry tub, SX1 / 2 CoD
SX2:- 2 x 60519814-xx Gantry tub, SX1/2 CoD
16 x 03097977-xx safety cover Y magnets SIPL.SX1
1 x 00375988-xx label: Warning of a magnetic field
1 x 00386029-xx label: Warning hand injuries
1 x 00386030-xx label warning for strong magnets
1 x 00195600-xx TI Safety note maglev, D + E
2 x 03097870-xx plastic wedge, 65 x 180mm
1 x 03097897-xx copper hammer, 750 g
Required spare parts
2 x 03077921 - guide rail MR S 25-154 (with red screw cap)
2 x 03083778 - guide rail MR S 25-1994 with red screw cap)
76 x 03068057 - ISO 4762 - M 5 x 25-12.9 geometric, 321 + VL.
Exchange guide rails
Lift preparation "2.2 Prepare Gantry lift" [ ➙ 16]
Preparing the Machine"2.3 Machine preparation" [ 16]
-Remove the magnets as described in "Replacing the magnets". "2.5 Exchange / Demounting of Y-Mag-
nets" [ ➙ 20]
Alternatively, the magnets can also remain in the machine and only with the cover be covered. But con-
sider the here still act magnetic forces and the rails should not come too close to them. Crushing.
Remove the gantrys as described by the gantry modularity
Disassembling guide rail
- Resolve the bolts of the guide rails and replace the guide rails through new ones. The new rails must
be mounted again in the same sequence and position.
Tighten all the bolts slightly and loosen them again with a half turn. The rails will be later pressed with
the excentric device Y leadership against the guide groove.
Now mount the magnets as described below under "Replacing the magnets".
Remove if required the spacer
Service Work
Replacement Y-Guide Rails Final Work
36 Service Manual (Internal) SIPLACE SX1/SX2/DX1/DX2
Among them was found a Teflon protector. This is to avoid that the magnets will be scratched.
Press with the lever the guide rail and tight the rail to the torque wrench with 10Nm.
Repeat this process until the whole bar on the guide rail and all screws are tight. If necessary, check it
using a feeler gauge, if the guide rails applied properly.
Check the position of the Y-magnets with the spacer for Y magnets 03065304-xx and point it out again,
if necessary. Please consider also the safety information in chapter "Changing the magnets.
Set the Y-leadership device, cpl. as shown in the image
of the magnets
acpage