4 – 121 Data ty pe Item Error conditions Placement of vision components (0.8 <= the smallest pitch < 1.0 mm) (Ball components) The optional 37.5 mm, 27 mm or 18 mm VCS is not set in Placement data of vision compone…

100%1 / 723
4 – 120
(3-4) Coherence check items: error conditions
Data type Item Error conditions
Line The line cannot handle Vision data. *1
Placement of vision
components (over 0.4 mm)
(Lead components)
The standard VCS or optional VCS (37.5 mm, 27 mm or
18 mm) is not set in Placement data of vision
components whose size is 0.4 mm or larger.
*1
Placement of vision
components (0.3 <= Pitch < 0.4
mm) (Lead components)
The optional VCS (37.5 mm, 27 mm or 18 mm) is not
set in Placement data of vision components whose pitch
is 0.3 mm or wider, but narrower than 0.4 mm.
*1
Placement of vision
components (0.2 <= Pitch < 0.3
mm) (Lead components)
The optional VCS (27 mm or 18 mm) is not set in
Placement data of vision components whose pitch is 0.2
mm or wider, but narrower than 0.3 mm.
*1
Placement of vision
components (0.135 <= Pitch <
0.2 mm) (Lead components)
The optional 18 mm VCS is not set in Placement data of
vision components whose pitch is 0.135 mm or wider,
but narrower than 0.2 mm.
*1
Placement of general vision
components (15 < the smallest
pitch <= 22 mm) (Lead
components)
The standard VCS is not set in Placement data of
general vision components whose minimum pitch is
wider than 15 mm, but 22 mm or narrower.
*1
Placement of general vision
components (11 < the smallest
pitch <=15 mm) (Lead
components)
The standard VCS or optional 37.5 mm VCS is not set
in Placement data of general vision components whose
minimum pitch is wider than 11 mm, but 15 mm or
narrower.
*1
Placement of general vision
components (6.5 < the smallest
pitch <= 11 mm) (Lead
components)
The standard VCS or optional 37.5 mm or 27 mm VCS
is not set in Placement data of general vision
components whose minimum pitch is wider than 6.5
mm, but 11 mm or narrower.
*1
Placement of general vision
components (0.5 <= the
smallest pitch <=6.5 mm)
(Lead components)
The standard VCS or optional 37.5 mm, 27 mm or 18
mm VCS is not set in Placement data of general vision
components whose minimum pitch is 0.5 mm or wider,
but 6.5 mm or narrower.
*1
Placement of general vision
components (0.4 <= the
smallest pitch <0.5 mm) (Lead
components)
The optional 37.5 mm, 27 mm or 18 mm VCS is not set
in Placement data of general vision components whose
minimum pitch is 0.4 mm or wider, but narrower than 0.5
mm.
*1
Placement of general vision
components (0.3 <= the
smallest pitch < 0.3 mm) (Lead
components)
The optional 27 mm or 18 mm VCS is not set in
Placement data of general vision components whose
minimum pitch is 0.3 mm or wider, but narrower than 0.4
mm.
*1
Placement of general vision
components (0.2 <= the
smallest pitch < 0.3 mm) (Lead
components)
The optional 18 mm VCS is not set in Placement data of
general vision components whose minimum pitch is 0.2
mm or wider, but narrower than 0.3 mm.
*1
Placement of vision
components (15 < the smallest
pitch <= 22 mm) (Ball
components)
The standard VCS is not set in Placement data of vision
components whose minimum pitch is wider than 15 mm,
but 22 mm or narrower.
*1
Placement of vision
components (11 < the smallest
pitch <15 mm) (Ball
components)
The standard VCS or optional 37.5 mm VCS is not set
in Placement data of vision components whose
minimum pitch is wider than 11 mm, but 15 mm or
narrower.
*1
Placement of vision
components (6.5 < the smallest
pitch <= 11 mm) (Ball
components)
The standard VCS or optional 37.5 mm or 27 mm VCS
is not set in Placement data of vision components
whose minimum pitch is wider than 6.5 mm, but 11 mm
or narrower.
*1
Vision data
Placement of vision
components (1.0 <= the
smallest pitch < 6.5 mm) (Ball
components)
The standard VCS optional 37.5 mm, 27 mm or 18 mm
VCS is not set in Placement data of vision components
whose minimum pitch is wider than 1.0 mm, but 6.5 mm
or narrower.
*1
*1: Items applicable to machines other than a KE-2030
4 – 121
Data type Item Error conditions
Placement of vision
components (0.8 <= the
smallest pitch < 1.0 mm) (Ball
components)
The optional 37.5 mm, 27 mm or 18 mm VCS is not set
in Placement data of vision components whose
minimum pitch is 0.8 mm or wider, but narrower than 1.0
mm.
*1
Placement of vision
components (0.5 <= the
smallest pitch < 0.8 mm) (Ball
components)
The optional 27 mm or 18 mm VCS is not set in
Placement data of vision components whose minimum
pitch is 0.5 mm or wider, but narrower than 0.8 mm.
*1
Placement of vision
components (0.35 <= the
smallest pitch < 0.5 mm) (Ball
components)
The optional 18 mm VCS is not set in Placement data of
vision components whose minimum pitch is 0.35 mm or
wider, but narrower than 0.5 mm.
*1
Pick-up of all balls or all lands
vision recognition components
The BGA vision recognition function cannot be used
with the station in Pick data of all balls or all lands vision
recognition components.
*1
Number of all balls or all lands
vision recognition ball pattern
components
The number of user-defined ball pattern components in
Pick data is found to exceed 10 with the all balls or all
lands vision recognition function.
*1
Error conditions of the VCS recognition type specified
on the MSL setup menu and the light type specified in
Light data
*1
VCS recognition type
Reflective
light
Penetra-
tive light
Side light
No recognition
×
×
×
BGA vision recognition
×
×
Penetrative recognition
×
×
Reflective recognition
×
×
BGA, penetrative
×
BGA, reflective
×
Penetrative, reflective
×
BGA, Penetrative, reflective
Light type
Vision data
Component for which you can
select “Vision centering
component” as its component
type
The component size is smaller than 0.6 mm. *1
4 – 122
Data type Item Error conditions
Optimization
option
Non-stop option
The IC recovery belt is used on the rear side although
“Front to Rear” is selected from the “Primary Secondary”
pull-down menu
- If the area is set to “front” or “rear”.
A DTS is installed on your system, and “No” is not selected
from the “Feeder” pull-down menu on the “Non-Stop”
option tab.
A tray holder is used and the menu item “Feeder” on the
“Non-stop” tab is not set to “No”.
- “Arrange priority” is set to a KE-2000 on the “Non-Stop”
tab.
(That is, the line includes a KE-2000 station, and the
“Arrange priority” is set to “Line” on the “Non-Stop” option
tab.
A belt feeder is used and the menu item “Feeder” on the
“Non-stop” tab is not set to “No”.
“No” is not selected from the “Feeder” pull-down menu on
the “Non-Stop” option tab even though the machine is not
designed for not-stop operation (this option is not installed
on the station).
*1: Items applicable to machines other than a KE-2030