KE-2030使用说明书 - 第245页
4 – 146 • Arrang e f eeders according to the placement peak point is fixed on center of the PW B Specify the calculation m ethod of the component placement peak point to assig n feeders. W hen this option is checked, the…

4 – 145
MTC/MTS Tray Priority
Specify whether the same type of components are to be assigned to an MTC or
MTS or assigned with giving the components feeding speed the highest priority.
Figure 4.10.1.15 MTC/MTS Tray Priority
• Group trays with same component type together:
Assigns the same type of components to an MTC or MTS.
• Arrange trays to optimize supply time:
Assigns components to an MTC or MTS with giving the component feeding
speed the highest priority.
Comp Type A
A
A
Comp Type B
B
B
Comp Type C
C
C
Comp Type A
Comp Type B
Comp Type C
A
B
C
A
B
C
When “Group trays with same
component type together” is selected
When “Arrange trays to optimize
supply time” is selected
Figure 4.10.1.16 Example of MTC/MTS Tray Priority
PCB/Circuit
Specify whether to optimize the entire board or a circuit.
Figure 4.10.1.17 PCB/Circuit
When you select “Optimize by circuit”, the system optimizes a circuit one by one.
When you select “Optimize by PCB”, the system optimizes each circuit as if
components are assigned on a single plane board.
• Order placements from smallest to largest nozzle size
Specify whether components are placed from ones which require the smallest
nozzle or not.
When this item is checked, the system optimizes the component placement order
so that components which use the smallest nozzle are placed first with ignoring the
priority specified with the “Place order” option.

4 – 146
• Arrange feeders according to the placement peak point is fixed on center of the
PWB
Specify the calculation method of the component placement peak point to assign
feeders.
When this option is checked, the system assigns feeders so that the center of a
board can be the component placement peak point.
When this option is not checked, the option selected in the “Placement peak”
pull-down box displayed in the “Feeder arrange” dialog box is activated.
(7) Non-stop operation
You can use the Optimization function to specify a station that is to perform the
Non-stop operation. When you use this option, you can replace components
without stopping the current production.
When you select the “Non-stop” tab, the following dialog box appears on the
screen.
Figure 4.10.1.18 “Non-stop” option tab
◇ When you check the check box “Line”, you can specify the Non-stop operation.
Figure 4.10.1.19 Specifying the Non-stop operation

4 – 147
− Feeder
Set the Non-stop operation of a feeder.
• No: The Optimization utility does not perform the Non-stop
operation.
• Tact priority: The Optimization utility assigns components with considering
the tact first.
• Arrange priority: The Optimization utility assigns components with considering
the feeder changeover first.
When you select “Arrange priority” with a KE-2020, an error occurs if the
system executes the line coherence check.
− Primary Secondary
Select which side to be used mainly in Non-Stop operation mode, front or rear.
• Front to Rear: The system performs PWB production with the front side mainly,
and uses the rear side when you replace components.
• Rear to Front: The system performs PWB production with the rear side mainly,
and uses the front side when you replace components.
− MTC/MTS
Select whether to allow an MTC and MTS to perform the Non-stop operation or
not.