KE-2030使用说明书 - 第263页

4 – 164 F-79 F-75 R-79 R-75 F-79 F-75 R-5 R-1 (2) W hen you select the [ Copy as point symmetry] command The selected f eeder is copied at t he opposite position so t hat a f eeder on the fr ont can be replaced with one …

100%1 / 723
4 – 163
In Head image display mode, the trackball cursor is displayed instead of the
head image figure. If you assign feeders according to the head assignments
and execute the Optimization utility, components will be very likely to be picked
up simultaneously.
Figure 4.11.1.14 Screen example in Head image display mode
Head image display mode is canceled when you click the left button of a
trackball or select the [Display head image] command again after opening the
pop-up menu.
Note:
Although it becomes likelier that feeders pick up components
simultaneously after you assign the feeders according to the head
assignments and execute the Optimization utility, those feeder may pick up
components at the same time as other feeders do.
The trackball arrow mark cursor position indicates the same position as the
reference head (normally the left head) of the head image cursor figure
indicates. When you move this reference head over the figure of a feeder,
and click the right button of a trackball, the copy operation functions rapidly.
7. Copy as line symmetry or Copy as point symmetry
These commands copies the selected feeder symmetrically with respect to a
line or point.
While dragging the trackball to enclose the feeder which is to be copied to
highlight it, press the right button of the trackball. The pop-up menu appears
on the screen as shown below.
Select either of the commands [Copy as line symmetry] or [Copy as point
symmetry].
If you select the front feeder, it is copied to the rear side, while if you select the
rear feeder, it is copied to the front side.
Figure 4.11.1.15 Pop-up menu
(1) When you select the [Copy as line symmetry] command
The selected feeder is copied at the position where the copied feeder fixing hole
faces the original feeder fixing hole.
4 – 164
F-79
F-75
R-79
R-75
F-79
F-75
R-5
R-1
(2) When you select the [Copy as point symmetry] command
The selected feeder is copied at the opposite position so that a feeder on the
front can be replaced with one on the rear at a time or vice versa.
When a feeder is copied symmetrically
with respect to a line
When a feeder is copied symmetrically
with respect to a point
Notes:
A tray component cannot be copied.
If any component was already assigned to the copy destination, the
following error message appears on the screen and any copy operation is
not performed.
Figure 4.11.1.16 Feeder copy error message
Note: If you select a feeder lying astride the front and rear sides, the system cannot
copy it.
8. Cop to left or right
This command copies the selected feeder to the left station or right station
(available to a KE-2030 only).
While dragging the trackball to enclose the feeder which is to be copied to
highlight it, press the right button of the trackball. The pop-up menu appears
on the screen. Select the [Copy to left or right] command.
Figure 4.11.1.17 Pop-up menu
4 – 165
When you select a feeder on the left station, it is copied to the right station,
while when you select a feeder on the right station, it is copied to the left station.
In both cases, the selected feeder is copied onto the same hole position of the
opposite station.
[Copy to left or right] command is executed.
Figure 4.11.1.18 Copy operation with the [Copy to left or right] command
Notes:
When you use a station other than a KE-2030, this menu item is displayed
in gray and you cannot select it.
A permanent component or tray component cannot be copied.
If you select a feeder lying astride the left station and right station, the
system cannot copy it.
If any component was already assigned to the copy destination, the error
message shown in Figure 4.11.1.16 appears on the screen, and the system
does not copy the feeder.