8 − 30 5) Board available out This item turns on and off the boar d available OUT signal. W hen the control item “Boar d available out” is checked, select the <O N>, <OFF> or <ON/ OFF> button or press t…
8 − 29
signal.

8 − 30
5) Board available out
This item turns on and off the board available OUT signal.
When the control item “Board available out” is checked, select the <ON>,
<OFF> or <ON/OFF> button or press the F3, F4 or F5 key to control the
board available OUT signal.
6) Conveyor in-motor
When the control item “Conveyor in-motor “ is selected, click the <ON>,
<OFF> or <ON/OFF> button or press the F3, F4 or F5 key.
The state display is updated when the transport motor (IN buffer) is
controlled completely.
7) Conveyor center-motor
This item turns on and off the transport motor (Center buffer).
When the control item “Conveyor center-motor” is selected, click the <ON>,
<OFF> or <ON/OFF> button or press the F3, F4 or F5 key.
The state display is updated when the transport motor (center buffer) is
controlled completely.
8) Conveyor out-motor
This item turns on and off the transport motor (OUT buffer).
When the control item “Conveyor out-motor” is selected, click the <ON>,
<OFF> or <ON/OFF> button or press the F3, F4 or F5 key.
The state display is updated when the transport motor (OUT buffer) is
controlled completely.
9) Support tbl. stp. snsr. (Support table stop sensor)
This item turns on and/or off the support table stopper.
When the control item “Support tbl. stp. snsr.” is selected, click the <ON>,
<OFF> or <ON/OFF> button or press the F3, F4 or F5 key.
The state display is updated when the support table stopper is controlled
completely.
10) Entrance shutter
This item opens/closes the entrance shutter cylinder.
When the control item “Entrance shutter” is selected, click the <OPEN>,
<CLOSE> or <OPEN/CLOSE> button or press the F3, F4 or F5 key.
The state display is updated when the entrance shutter cylinder is
controlled completely.
8 − 31
11) Exit shutter
This item opens/closes the exit shutter cylinder.
When the control item “Exit shutter” is selected, click the <OPEN>,
<CLOSE> or <OPEN/CLOSE> button or press the F3, F4 or F5 key.
The state display is updated when the exit shutter cylinder is controlled
completely.
(4) State display
The state of each sensor and each unit is displayed when the sensor and unit
are controlled completely.
The state of each sensor, signal, and unit is always displayed.