KE-2030使用说明书 - 第577页
8 − 44 8.4 Feeder Knock Pin Control W hen y ou select the [ Feeder] com mand on the [Ct rl] menu, then the [Feeder knock pin control] com mand, t he following “Feeder knock pin control” dialog box appears. Figure 8.4.1 F…

8 − 43
1) Vacuum
When the radio button “Vacuum” is checked, you can turn on/off vacuum of
the vacuum table.
When the radio button “Vacuum” is checked, click the <ON>, <OFF> or
<ON/OFF> button or press the F3, F4 or F5 button.
The “State” display is updated when the selected vacuum function is
controlled completely.
2) Blow cont
When the radio button “Blow cont” is checked, you can turn on/off the blow
function of the vacuum table.
When the radio button “Blow cont” is checked, click the <ON>, <OFF>, or
<ON/OFF> button, or press the F3, F4 or F5] key.
The state display is updated when the selected blow function is controlled
completely.
3) Support table
When the radio button “Support table” is checked, you can move up or
down the support table.
When the radio button “Support table” is checked, click the <UP>,
<DOWN> or <UP/DOWN> button, or press the F3, F4 or F5] key.
(3) State
This column shows the condition of each unit when controlled completely.

8 − 44
8.4 Feeder Knock Pin Control
When you select the [Feeder] command on the [Ctrl] menu, then the [Feeder knock
pin control] command, the following “Feeder knock pin control” dialog box appears.
Figure 8.4.1 Feeder knock pin control screen
(1) Control item
Select a control item with the corresponding radio button.
You can select the control item on the FPI control only when the “Feeder position
indicator” is checked (installed) on the “Option” menu of the MS parameter.
This selection does not affect the setting of the “Device enable” menu invoked
from the Machine Setup menu (this means that you can select a not-checked
unit).
(2) Control position
When selecting “Tape feeding action” as the control item, select the position of
the pin to be controlled from the control side (using the radio button) and the
number (using the edition box).

8 − 45
When selecting “Direct knock action” in the control items, select the position of
the pin to be controlled from the control side (using the radio button).
(3) Kind of feeder
When selecting “Tape feeding action” as the control item, select the tape width
and feed pitch from the combo box.
This item cannot be set when the control item “Direct knock action” is selected.
The following list appears when you press the ALT key and ↓ key at the same
time.
Tape width
The available feed pitches vary depending on the tape width you selected.