SPECIFICATIONS
Item
Specifications
Mounting angle
0
°
to 359
°
(It can be set in increments of 0.01°.)
Mounting range
Refer to the Reference Manual.
Board flow direction
Refer to the Reference Manual.
Control system
Microcomputer system
External memory
Data is saved in PT. (Approximately 1 MB is required for saving a piece of data, depending on the
hard disk space of PT.) One type per 3.5-inch floppy disk
Program data
∗
1
Point count: Max. 10000 points
Machine body
Normal service source: Three-phase 200
±
10 VAC or 400
±
20 VAC
Frequency: 50/60 Hz
Peak current
value during
operation
CM401-M: 18 A
CM401-L: 15 A
CM402-M: 27 A
CM402-L: 20 A
Rated voltage 200 VAC: Measured based on our aging data
Take this into account when choosing the primary power
supply AVR (Stabilized power supply), etc.
(The peak current value varies depending on the operation
data.)
Power source
Power supply for
HUB
∗
3
Single-phase 100 VAC to 240 VAC, Frequency: 50/60 Hz
Machine body
CM401-M: 1.7 kVA
CM401-L: 1.6 kVA
CM402-M: 3.5kVA
CM402-L: 2.5 kVA
Rated capacity
Power supply for
HUB
∗
3
140 VA
Supply air pressure
0.49 MPa to 0.78 MPa (Working air pressure: 0.49 MPa to 0.54 MPa)
Supply air volume
150 L/min (A.N.R)
Outside dimension
CM401-M: 1260 mm (W)
×
2460 mm (D)
×
1430 mm (H)
CM401-L: 1260 mm (W)
×
2690 mm (D)
×
1430 mm (H)
CM402-M: 2350 mm (W)
×
2460 mm (D)
×
1430 mm (H)
CM402-L: 2350 mm (W)
×
2690 mm (D)
×
1430 mm (H)
∗
Three-color signal tower and color touch panels not included
Mass
∗
2
CM401-M: 1500
kg
(Standard configuration, excluding a collectively changing truck)
CM401-L: 1665
kg
(Standard configuration, excluding a collectively changing truck)
CM402-M: 2700
kg
(Standard configuration, excluding a collectively changing truck)
CM402-L: 3000
kg
(Standard configuration, excluding a collectively changing truck)
∗
(One) Collectively changing truck: 140
kg
Environmental
condition
Temperature: 10
°
C to 35
°
C
Humidity: 25% RH to 75% RH (No condensation)
Transportation and
storage condition
Temperature:
−
20
°
C to 60
°
C
Humidity: 75% RH or less (No condensation)
Altitude
1000 m or less, above sea level
Noise
< 70 dB (A)
∗
1: Data is created by PT.
This machine can only modify some data.
∗
2: Mass of the main body excluding the optional units
∗
3: The power supply for HUB is an option. This power supply is required when you wish to
communicate with PT while the main power supply is OFF.
4Y3C-E-PLA00-A01-04

Page 1
お客様へ
For Our Customers
■ パーツリストは、3 種類のパーツリストがあります。
※ テープフィーダ、ノズルパーツリストに関しては御購入されたお客様にのみ付属します。
■ The parts list is divided into the following 3 books.
※ Only the customer who has purchased the tape feeder or the nozzle is provided with its
parts list.
機種別 パーツリスト
お買い上げ頂いた機種のユニットおよび、パーツ、
キット、キット部品を、機種別に記載しています。
Parts list for individual machine
The Units,parts,kits and Kit parts of the
machine you purchased are described for
individual machine.
その他バルクフィーダ、
チューブフィーダ、振動スティック
フィーダがあります。
We have prepared the parts lists
for bulk feeder,tube feeder,and
stick feeder.
テープフィーダ
テープフィーダに関するユニット
およびキット、キット部品をテープの
種別ごとに記載しています。
Tape Feeder
The units,kits,and kit parts
related to tape feeder are
described for each type of tape.
ノズルパーツリスト
ノズルのキットおよび、キット部品を記載
しています。
Nozzle Parts List
The parts and kits of nozzle are
described.

Page 2
■ パーツリストに使用しております「製品」・「キット」・「パーツ」の3つの言葉は
下図のような状態により、使い分けています。
※ テープフィーダに関しては御購入されたお客様にのみ付属します。
■ The following 3 words “Model” “Unit” “Parts” means different parts as the figure below.
※ Only the customer who has purchased the tape feeder is provided with its parts list.
製品(機械)
Model (Machine)
キット
Kit
キット
Kit
パーツ
Part
パーツ
Part
テープフィーダユニット
Tape feeder unit
キット
Kit
パーツ
Part
パーツ
Part
機種別パーツリストを
参照してください。
Refer to “Parts list for
individual machine”.
テープフィーダパーツリストを
参照してください。
Refer to “Tape Feeder
Parts List”.