Host Computer System.pdf - 第100页
AVK3 HOST COMPUTER SYSTEM 3.10 Upl oading Rotary Chuck Inform a t ion D77HEC-54- 090-A0 3.10- 1 3.10. Uploading R otar y Chuck Inf ormation D77HEC - 54-090-A 0 3.10. 1 Upl oading Rotary Chuck Information W ith A VK3, if …

AVK3
HOST COMPUTER SYSTEM
3.9 Uploading Feeder Information
D77HEC-54-040-A0
3.9-4

AVK3
HOST COMPUTER SYSTEM
3.10 Uploading Rotary Chuck Information
D77HEC-54-090-A0
3.10-1
3.10. Uploading Rotary Chuck Information
D77HEC-54-090-A0
3.10.1 Uploading Rotary Chuck Information
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal rotary chuck information and then can read the rotary chuck information (using C1 command) sent to
the AVK3.
Data details
1) -1
C1Rnnn
1
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1 Total designation 3 000 to 900
×
=000: Sub-total
(no clear after upload)
=900: Grand total
(clear after upload)
(≠900 is sub-total)
1) -2
D0SDnnnn / nn / nn nn : nn
1 2 3 4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Collection start
date
2
×
Output command for the
production information
collection start date
2 Year (AD) 4 1991 to 2nnn
×
Corresponding to AD 2000
3 Month 2 01 to 12
×
4 Date 2 01 to 31
×
5 Hour 2 00 to 23
×
6 Minute 2 00 to 59
×
STX
C 1 R x
No. of
characters
ETX
1
x x
Check sum

AVK3
HOST COMPUTER SYSTEM
3.10 Uploading Rotary Chuck Information
D77HEC-54-090-A0
3.10-2
1) -3
D0EDnnnn / nn / nn nn : nn
1 2 3 4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Collection end
date
2
×
Output command for the
production information
collection end date
2 Year (AD) 4 1991 to 2nnn
×
Corresponding to AD 2000
3 Month 2 01 to 12
×
4 Date 2 01 to 31
×
5 Hour 2 00 to 23
×
6 Minute 2 00 to 59
×
1) -4
D0HnTnnnnnnnnnnEnnnnnnnnnnInnnnnnnnnn
1 2 3 4 5
Pnnnnnnnnnn
RnnnnnnWn
6 7 8
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
26 mm chuck
command
1
×
Output command for the 26
mm rotary chuck information
2 Chuck No. 1 1 to 4
×
3
Parts chuck
count
10 0 to 999999999
×
4
Insertion error
count
10 0 to 999999999
×
5
No. of insertion
points
10 0 to 999999999
×
6
Parts remove
count
10 0 to 999999999
×
7 Insertion rate 6 0 to 100000
×
1 / 1000% increments
8
Maintenance
warning
1 0 to 1
×
0 = Insertion rate more than
99.01
1 = Insertion rate less than
99.00