AVK3 HOST COMPUTER SYSTEM 3.13 Upl oadi ng Z D iv i s i on Mode and L/R Sel ect i on D77HEC-54- 120-A0 3.13- 2  Protocol  Condition  Can be used in standar d specif icati on.  Vali d i n O NLINE m ode only .  Af ter…

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
3.13 Uploading Z Division Mode and L/R Selection
D77HEC-54-120-A0
3.13-1
3.13. Uploading Z Division Mode and L/R Selection
D77HEC-54-120-A0
3.13.1 Uploading Z Division Mode and L/R Selection
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal Z division mode and then can read the Z division mode (using C1 command) sent to the AVK3.
Data details
AVK3 Host computer
1) -1
D0xx xx
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1 Z mode 2
×
= PE: Priority mode
= EX: Exchange mode
= PR: Preparation mode
= CN: Connection mode
2 Reserve 2 Space
×
For expansion
3 L/R selection 2
×
= ZL: ZL selection
= ZR: ZR selection
= : If connection mode
STX
C 1 Z M
No. of
characters
ETX
Check sum
STX
D 0
No. of
characters
ETX
Check sum
1) -1
AVK3
HOST COMPUTER SYSTEM
3.13 Uploading Z Division Mode and L/R Selection
D77HEC-54-120-A0
3.13-2
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE mode only.
After receiving ‘A2’ from HOST, the processing ends.
Start of upload
Host computer
Sends out mode.
AVK3
D 0 Division mode and selection
C1ZM
A 0
A 2
End of reception
End of transmission
AVK3
HOST COMPUTER SYSTEM
3.14 Uploading Parts Data Directory
D77HEC-54-130-A0
3.14-1
3.14. Uploading Parts Data Directory
D77HEC-54-130-A0
3.14.1 Uploading Parts Data Directory
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal parts data directory and then can read the parts data directory (using C1 command) sent to the
AVK3.
Data details
AVK3 Host computer
1) -1
D0yyyy / mm / ddD -
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1 Changed date
10
( / included)
×
yyyy = Year (AD)
mm = 01 to 12
dd = 01 to 31
2 Program name 16
× ×
If the characters of the control
No. and name are less than
16 digits, output will be up to
the registered length.
STX
C 1
No. of
characters
ETX
Check sum
S
STX
D 0
No. of
characters
ETXCheck sum