Host Computer System.pdf - 第128页

AVK3 HOST COMPUTER SYSTEM 5.1 Inqui ring and Alter ing NC Program Na m e D77HEC-50- 400-A0 5.1- 1 5.1. Inquiring and A ltering NC Program Nam e D77HEC - 50-400-A 0 5.1.1 Inquiri ng a nd A ltering NC Program N ame If the …

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
5. INQUIRING AND ALTERING PROGRAMS
D77HEC-50-000-A0
5-2
D77HEC-50-000-A0
5. INQUIRING AND ALTERING
PROGRAMS
AVK3
HOST COMPUTER SYSTEM
5.1 Inquiring and Altering NC Program Name
D77HEC-50-400-A0
5.1-1
5.1. Inquiring and Altering NC Program Name
D77HEC-50-400-A0
5.1.1 Inquiring and Altering NC Program Name
If the host computer gives C3 command to AVK3, the NC program names filled in AVK3 can be inquired
and/or altered.
Inquiring and alteration processing will end when A2 command is sent from the host computer.
Data details
No. Data name
Max.
digits
Input range Omit
Vari-
able
Remarks
1
Program control
No.
3 000 to FFF
If less than 3 digits, ‘0’ is affixed
to the front.
Ex.) P1 P001
If omitted, the execution
program is to be inquired or
altered.
Even if a program name is
added, the name is ignored.
NC program names can be altered by giving D1 command from the host computer.
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Program control
No.
3 000 to FFF
×
Inquiry control No. and
alteration control No. must
agree.
If control No. with Host AVK3
only, the (change) name is
eliminated.
If less than 3 digits, ‘0’ is added
in the front to make 3 digits.
2 Program name 12
‘0’ to ‘9’
‘A’ to ‘Z
Special character
×
If blank spaces are added by
alteration, the spaces will be
ignored.
Ex.) P001ABC P001ABC
STX
C 3 P x
No. of
characters
ETX
1
x x
Check sum
STX
C 3 P x
No. of
characters
1
x x
Check sum
ETX
Program name
(Up to 12 characters)
<Can be omitted>
2
AVK3
HOST COMPUTER SYSTEM
5.1 Inquiring and Altering NC Program Name
D77HEC-50-400-A0
5.1-2
Protocol
Condition
Can be used in optional specification.
Valid in ONLINE mode only.
If an unregistered program is designated, ‘A4E00’ is returned.
If the control No. to be inquired to and the control No. to be altered differ, ‘A4E00’ is returned.
Alteration can be made as often as possible until ‘A2’ is received.
Start of inquiring and
altering
Host computer
Sends out monitoring
data.
AVK3
C3P Control No.: 3 digits
D 1 P Control No.: 3 digits
A2
Name
Sends out altered result.
D 1
P Control No.: 3 digits
Altered name
D 1
P Control No.: 3 digits
A2
Name
Inquiry
Alteration