Host Computer System.pdf - 第136页

AVK3 HOST COMPUTER SYSTEM 5.4 Insert ing Executi on Progr a m i nto NC Data D77HEC-50- 430-A0 5.4- 3  Example of NC data insertion <NC data i n AVK3> NC data before inserti on NC data after insertion N001 d1d1 …… …

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
5.4 Inserting Execution Program into NC Data
D77HEC-50-430-A0
5.4-2
Protocol
Start of insertion
Host computer
Requests data.
AVK3
C4AL
A 0
Sends updated data.
D 1 Block No. NC data
D 1 Block No.
A2
NC data
Transfers inserted
data.
AVK3
HOST COMPUTER SYSTEM
5.4 Inserting Execution Program into NC Data
D77HEC-50-430-A0
5.4-3
Example of NC data insertion
<NC data in AVK3>
NC data before insertion NC data after insertion
N001 d1d1……
N002 d2d2……
N003 d3d3……
N004 d4d4……
N005 d5d5……
N006 d6d6……
N007 d7d7……
N001 d1d1……
N002 (1) data
N003 d2d2……
N004 d3d3……
N005 (2) data
N006 (3) data
N007 d4d4……
N008 d5d5……
N009 d6d6……
Condition
Can be used in optional specification.
Valid in ONLINE mode only.
If execution program is not selected, ‘A4E00’ is returned.
Can be inserted as often as possible until ‘A2’ is received.
If received during operation, ‘A4E00’ is returned.
Start of insertion
Host computer
Sends insertion result.
AVK3
C4IN
A 0
Sends insertion result.
A2
Inserted data
D 1 N002 (1) data
D 1 N002 (1) data
D 1 N004 (2) data
D 1 N005 (2) data
D 1 N004 (3) data
D 1 N006 (3) data
Inserted data
Inserted data
Insertion end
Sends insertion result.
AVK3
HOST COMPUTER SYSTEM
5.4 Inserting Execution Program into NC Data
D77HEC-50-430-A0
5.4-4