AVK3 HOST COMPUTER SYSTEM 6.1 Remot e Control: C5 D77HEC-55- 010-A0 6.1- 3  Z data alteration co mmand If parts are ex haus t ed in the f eeder carri age, this can alter Z data where parts ex haustion oc curred. = R E M…

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
6.1 Remote Control: C5
D77HEC-55-010-A0
6.1-2
PC board convey control command
No. Subcommand Data name Remarks
LP PC board unload inhibit
command
Inhibits unloading of PC board from magazine. 1
UP PC board sweep out
command
Sweeps out PC board from XY table.
Magazine stocker control command
No. Subcommand Data name Remarks
None Unloader magazine
sweep out command
Sweeps out magazine from unloader.
UM Unloader magazine
sweep out command
Sweeps out magazine from unloader.
1
LM Loader magazine sweep
out command
Sweeps out magazine from loader.
Mode switching command
No. Subcommand Data name Remarks
O1 ONLINE running lamp ON command Turns ONLINE running lamp ON. 1
O2 ONLINE running lamp OFF
command
Turns ONLINE running lamp OFF.
=REMARKS=
C5O2xx
1
No. Data name
Max.
digits
Sup-
press
Vari-
able
Input range Remarks
ML Switching manual mode
SA Switching semiauto mode
1 Mode 2
× ×
FA
Switching auto mode
STX
C 5
No. of
characters
ETX
1
Check sum
STX
C 5 S K
No. of
characters
ETX
1
Check sum
STX
C 5
No. of
characters
ETX
1
Check sum
AVK3
HOST COMPUTER SYSTEM
6.1 Remote Control: C5
D77HEC-55-010-A0
6.1-3
Z data alteration command
If parts are exhausted in the feeder carriage, this can alter Z data where parts exhaustion occurred.
=REMARKS=
Z***
Z***
1 2
No. Data name
Max.
digits
Input range Omit
Vari-
able
Remarks
1 Parts exhaust 3 001 to 121
×
Z121 is a jumper.
Z axis No. where parts
exhaustion occurred.
2 Z axis No. 3 001 to 121
×
Z121 is a jumper.
Newly registered Z axis No.
NC program selection
=REMARKS=
P***
1
No. Data name
Max.
digits
Input range Omit
Vari-
able
Remarks
1
Program
control No.
3 000 to FFF
×
If other than the valid character
within 3 digits, it becomes an
error.
If less than 3 digits, ‘0’ is affixed
to the front.
Ex.) P1 P001
Even if a program name is
added after the control No., the
name is ignored.
If unregistered, it becomes an
error.
STX
C 5 S E
No. of
characters
ETX
Remarks
Check sum
STX
C 5 S E
No. of
characters
ETX
Remarks
Check sum
AVK3
HOST COMPUTER SYSTEM
6.1 Remote Control: C5
D77HEC-55-010-A0
6.1-4
Parts program selection command
Enables to select parts program registered in AVK3.
=REMARKS=
U***
1
No. Data name
Max.
digits
Input range Omit
Vari-
able
Remarks
1
Program
control No.
3 000 to FFF
×
If other than the valid character
within 3 digits, it becomes an
error.
If less than 3 digits, ‘0’ is affixed
to the front.
Ex.) U1 U001
Even if a program name is
added after the control No., the
name is ignored.
If unregistered, it becomes an
error.
Z division mode, L/R selection command
Enables to select NC program registered in AVK3.
=REMARKS=
C5SEZxx
xx
1 2 3
No. Data name
Max.
digits
Omit
Vari-
able
Input range Remarks
PE Priority mode
EX Exchange mode
PR Preparation mode
1 Z division mode 2
× ×
CN
Connection mode
2 Reserve 2
× ×
Space
For expansion
ZL ZL selection
ZR ZR selection
3 Z selection 2
× ×
Space
Connection mode
STX
C 5 S E
No. of
characters
ETX
Remarks
Check sum
STX
C 5 S E
No. of
characters
ETX
Remarks