Host Computer System.pdf - 第155页
AVK3 HOST COMPUTER SYSTEM 6.1 Remot e Contr o l : C5 D77HEC-55- 010-A0 6.1- 4 Parts program selection co mmand Enables to select parts progra m reg i stered in AVK3. = R E M A R K S = U *** 1 No. Data name Max. digit s…

AVK3
HOST COMPUTER SYSTEM
6.1 Remote Control: C5
D77HEC-55-010-A0
6.1-3
Z data alteration command
If parts are exhausted in the feeder carriage, this can alter Z data where parts exhaustion occurred.
=REMARKS=
Z***
Z***
1 2
No. Data name
Max.
digits
Input range Omit
Vari-
able
Remarks
1 Parts exhaust 3 001 to 121
×
Z121 is a jumper.
Z axis No. where parts
exhaustion occurred.
2 Z axis No. 3 001 to 121
×
Z121 is a jumper.
Newly registered Z axis No.
NC program selection
=REMARKS=
P***
1
No. Data name
Max.
digits
Input range Omit
Vari-
able
Remarks
1
Program
control No.
3 000 to FFF
×
If other than the valid character
within 3 digits, it becomes an
error.
If less than 3 digits, ‘0’ is affixed
to the front.
Ex.) P1 → P001
Even if a program name is
added after the control No., the
name is ignored.
If unregistered, it becomes an
error.
STX
C 5 S E
No. of
characters
ETX
Remarks
* *
Check sum
STX
C 5 S E
No. of
characters
ETX
Remarks
* *
Check sum

AVK3
HOST COMPUTER SYSTEM
6.1 Remote Control: C5
D77HEC-55-010-A0
6.1-4
Parts program selection command
Enables to select parts program registered in AVK3.
=REMARKS=
U***
1
No. Data name
Max.
digits
Input range Omit
Vari-
able
Remarks
1
Program
control No.
3 000 to FFF
×
If other than the valid character
within 3 digits, it becomes an
error.
If less than 3 digits, ‘0’ is affixed
to the front.
Ex.) U1 → U001
Even if a program name is
added after the control No., the
name is ignored.
If unregistered, it becomes an
error.
Z division mode, L/R selection command
Enables to select NC program registered in AVK3.
=REMARKS=
C5SEZxx
xx
1 2 3
No. Data name
Max.
digits
Omit
Vari-
able
Input range Remarks
PE Priority mode
EX Exchange mode
PR Preparation mode
1 Z division mode 2
× ×
CN
Connection mode
2 Reserve 2
× ×
Space
For expansion
ZL ZL selection
ZR ZR selection
3 Z selection 2
× ×
Space
Connection mode
STX
C 5 S E
No. of
characters
ETX
Remarks
* *
Check sum
STX
C 5 S E
No. of
characters
ETX
Remarks
* *
Check sum

AVK3
HOST COMPUTER SYSTEM
6.1 Remote Control: C5
D77HEC-55-010-A0
6.1-5
Protocol
Condition
Can be used in optional specification.
Except for C501 command (ONLINE running lamp ON command), valid in ONLINE mode only.
It ends with receipt of ‘A2’ from the HOST.
PCB data selection command
Data details
C5SEC* - *
1
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1 Program name 15
‘0’ to ‘9’
‘A’ to ‘Z’
Special character
×
If other than the valid character,
‘A4E00’ is returned.
If the name is not registered,
‘A4E00’ is returned.
Start of remote control
Host computer
Start in 1 Block mode
End
AVK3
C5 STBL
A2
R1 ST
A2
Information that AVK3
has started
End