Host Computer System.pdf - 第32页

AVK3 HOST COMPUTER SYSTEM 2.4 Downloadi ng Indiv idual Machine Dat a D77HEC-52- 050A0 2.4- 1 2.4. Downloading Indiv idual Mac hine Data D77HEC - 52-050A 0 2.4.1 Downl oading Individua l Machine Data From A VK3, when the …

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
2.3 Downloading P.C.B. Data
D77HEC-52-030-A1
2.3-2
Protocol
Condition
Automatic width control can be used validly.
Valid in ONLINE mode only.
The data becomes valid when EOP () is received and the processing normally ends down to A2.
(If the processing ends abnormally in downloading, the data will be cleared.)
If the same program as the one in the memory is specified and the processing ends abnormally, the
program in the memory is deleted.
If the program currently being executed is downloaded during operation, ‘A4E00’ is returned.
Start of download
Host computer
Requests next data.
AVK3
D 0 PCB data
A 0
C0C
Control No.:
3 digits
Program name (Up
to 12 characters)
D 0
Transfers NC data.
A 0
Transfers NC data.
Requests next data.
End of transmission
End of reception
A 0
Creates a directory.
Stores the received NC
data in RAM.
AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-1
2.4. Downloading Individual Machine Data
D77HEC-52-050A0
2.4.1 Downloading Individual Machine Data
From AVK3, when the host computer sends C0 command to the individual machine data in AVK3, the AVK3
goes into receiving mode, and as a result, can read the individual machine data (C0 command is used) sent
to it.
Data details
When the machine receives the C0 command, an A0 command is returned as acknowledgment.
The host computer receives this A0 command, and using D command (Data transfer command) sends
leading group (one group) of individual machine data to the AVK3.
1) – 1
D0OCAnBnCnDnEnFnGnHnInJnKnLnMnNnOn
1 2 3 4 5 6 7 8 9 10111213 14 15 16
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Operation
condition
command
2
× ×
Acknowledges as the set data
of movement condition.
When it is omitted, the
following data will be ignored.
2 Z mode 1 0 to 3
×
0 = Priority, 1 = Exchange,
2 = Preparation, 3 =
Connection
3 Priority Z axis 1 0 to 1
×
0 = ZL, 1 = ZR
4 Transfer 1 0 to 2
×
0 = Yes, 1 = No, 2 = Pass
5 Parts prefetch 1 0 to 1
×
0 = Yes, 1 = No
6
In recognition
error
1 0 to 1
×
0 = Continue, 1 = Stop
7 Recovery end 1 0 to 1
×
0 = Continue, 1 = Stop
8 All holes offset 1 0 to 1
×
0 = Yes, 1 = No
9
Optional hole
offset
1 0 to 1
×
0 = Yes, 1 = No
10
PCB
displacement
offset
1 0 to 1
×
0 = Yes, 1 = No
11
PCB inclination
offset
1 0 to 1
×
0 = Yes, 1 = No
12
Modification
offset
1 0 to 1
×
0 = Yes, 1 = No
13
θ axis offset
1 0 to 1
×
0 = Yes, 1 = No
14 Pitch offset 1 0 to 1
×
0 = Yes, 1 = No
15 1st hole offset 1 0 to 1
×
0 = Yes, 1 = No
16
Exchange
connection
1 0 to 1
×
0 = Yes, 1 = No
STX
C 0 G
No. of
characters
ETX
Check sum
STX
D 0
No. of
characters
ETX Check sum
1) -1 to 33
AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-2
=REMARKS=
If the data of 2 to 16 is out of the effective range, ‘A4E01’ is returned.
1) – 2
D0AGAnBnCn
1 2 3 4
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1 Aging command 2
× ×
Acknowledges as the set data
of aging.
When it is omitted, the
following data will be ignored.
2 Aging mode 1 0 to 1
×
Aging mode
0 = Valid, 1 = Invalid
3 Anvil short 1 0 to 1
×
Anvil short
0 = Valid, 1 = Invalid
4 Parts detection 1 0 to 1
×
Parts detection
0 = Valid, 1 = Invalid
=REMARKS=
If the data of 2 to 4 is out of the effective range, ‘A4E01’ is returned.
1) - 3
D0PRAnBn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Parts remove
support
command
2
× ×
Acknowledges as the set data
of parts remove support
command.
When it is omitted, the
following data will be ignored.
2
Parts remove
support
1 0 to 1
×
Parts remove support
0 = Invalid, 1 = Valid
3 Support position 1 0 to 1
×
Support position
0 = Bottom of camera,
1 = Table origin
1) - 4
D0ECAnBnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Parts exhaust
retry command
2
× ×
Acknowledges as the set data
of parts exhaust retry
command.
When it is omitted, the
following data will be ignored.
2 Retry setting 1 0 to 1
× ×
Retry setting
0 = Invalid, 1 = Valid
3 Retry count 2 0 to 99
×
Retry count