Host Computer System.pdf - 第34页
AVK3 HOST COMPUTER SYSTEM 2.4 Downloadi ng Indiv idual Machine Dat a D77HEC-52- 050A0 2.4- 3 1) -5 D0ER Fn 1 2 No. Data name Max. digit s Input r ange Sup- press Vari- abl e Remarks 1 EOP reco v ery comm and 2 × × Ac…

AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-2
=REMARKS=
If the data of 2 to 16 is out of the effective range, ‘A4E01’ is returned.
1) – 2
D0AGAnBnCn
1 2 3 4
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1 Aging command 2
× ×
Acknowledges as the set data
of aging.
When it is omitted, the
following data will be ignored.
2 Aging mode 1 0 to 1
×
Aging mode
0 = Valid, 1 = Invalid
3 Anvil short 1 0 to 1
×
Anvil short
0 = Valid, 1 = Invalid
4 Parts detection 1 0 to 1
×
Parts detection
0 = Valid, 1 = Invalid
=REMARKS=
If the data of 2 to 4 is out of the effective range, ‘A4E01’ is returned.
1) - 3
D0PRAnBn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Parts remove
support
command
2
× ×
Acknowledges as the set data
of parts remove support
command.
When it is omitted, the
following data will be ignored.
2
Parts remove
support
1 0 to 1
×
Parts remove support
0 = Invalid, 1 = Valid
3 Support position 1 0 to 1
×
Support position
0 = Bottom of camera,
1 = Table origin
1) - 4
D0ECAnBnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Parts exhaust
retry command
2
× ×
Acknowledges as the set data
of parts exhaust retry
command.
When it is omitted, the
following data will be ignored.
2 Retry setting 1 0 to 1
× ×
Retry setting
0 = Invalid, 1 = Valid
3 Retry count 2 0 to 99
×
Retry count

AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-3
1) -5
D0ERFn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
EOP recovery
command
2
× ×
Acknowledges as the EOP
recovery command.
When it is omitted, the
following data will be ignored.
2
EOP recovery
setting
1 0 to 1
× ×
EOP recovery setting
0 = Not used, 1 = Used
1) - 6
D0RSFn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Insertion error
non-clear
command
2
× ×
Acknowledges as the insertion
error non-clear command.
When it is omitted, the
following data will be ignored.
2
Insertion error
non-clear
setting
1 0 to 1
× ×
Insertion error non-clear
setting
0 = Can be cleared with
“RESET”.
1 = Cannot be cleared with
“RESET”.
1) - 7
D0JWFn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Jumper wire
waste reduction
command
2
× ×
Acknowledges as the jumper
wire waste reduction
command.
When it is omitted, the
following data will be ignored.
2
Jumper wire
waste reduction
function setting
1 0 to 1
× ×
Jumper wire waste reduction
function setting
0 = Invalid, 1 = Valid
1) - 8
D0RPnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Command by
production count
2
× ×
Acknowledges as the set data
of production count.
When it is omitted, the
following data will be ignored.
2 Count 2 0 to 99
× ×
Count

AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-4
1) - 9
D0ARnRnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Automatic
recovery
command
2
× ×
Acknowledges as the set data
of automatic recovery.
When it is omitted, the
following data will be ignored.
2 Recovery setting 1 0 to 1
× ×
Recovery setting
0 = Valid, 1 = Invalid
3 Recovery count 2 1 to 99
×
Recovery count
=REMARKS=
If the data of 2 is out of the effective range, ‘A4E01’ is returned.
1) - 10
D0DTDn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Data type
command
2
× ×
Acknowledges as the set data
of data type.
When it is omitted, the
following data will be ignored.
2 Data type 1 0 to 1
×
0 = ABS, 1 = INC
1) - 11
D0MAX (±) nnnnnnY (±) nnnnnnL (±) nnnnnn
1 2 3 4
R (±) nnnnnn
H (±) nnnnnnA (±) nnnnnn
5 6 7
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Machine offset 1
command
2
× ×
Acknowledges as the set data
of machine offset 1.
When it is omitted, the
following data will be ignored.
2 X offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
3 Y offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
4 ZL offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
5 ZR offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
6 WH offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
7 WA offset 7
-999999 to
+999999
Max. digit includes ±.