Host Computer System.pdf - 第35页

AVK3 HOST COMPUTER SYSTEM 2.4 Downloadi ng Indiv idual M achi ne Dat a D77HEC-52- 050A0 2.4- 4  1) - 9 D0ARnRnn 1 2 3 No. Data name Max. digit s Input r ange Sup- press Vari- abl e Remarks 1 Auto m atic reco v ery comm …

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-3
1) -5
D0ERFn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
EOP recovery
command
2
× ×
Acknowledges as the EOP
recovery command.
When it is omitted, the
following data will be ignored.
2
EOP recovery
setting
1 0 to 1
× ×
EOP recovery setting
0 = Not used, 1 = Used
1) - 6
D0RSFn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Insertion error
non-clear
command
2
× ×
Acknowledges as the insertion
error non-clear command.
When it is omitted, the
following data will be ignored.
2
Insertion error
non-clear
setting
1 0 to 1
× ×
Insertion error non-clear
setting
0 = Can be cleared with
“RESET”.
1 = Cannot be cleared with
“RESET”.
1) - 7
D0JWFn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Jumper wire
waste reduction
command
2
× ×
Acknowledges as the jumper
wire waste reduction
command.
When it is omitted, the
following data will be ignored.
2
Jumper wire
waste reduction
function setting
1 0 to 1
× ×
Jumper wire waste reduction
function setting
0 = Invalid, 1 = Valid
1) - 8
D0RPnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Command by
production count
2
× ×
Acknowledges as the set data
of production count.
When it is omitted, the
following data will be ignored.
2 Count 2 0 to 99
× ×
Count
AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-4
1) - 9
D0ARnRnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Automatic
recovery
command
2
× ×
Acknowledges as the set data
of automatic recovery.
When it is omitted, the
following data will be ignored.
2 Recovery setting 1 0 to 1
× ×
Recovery setting
0 = Valid, 1 = Invalid
3 Recovery count 2 1 to 99
×
Recovery count
=REMARKS=
If the data of 2 is out of the effective range, ‘A4E01’ is returned.
1) - 10
D0DTDn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Data type
command
2
× ×
Acknowledges as the set data
of data type.
When it is omitted, the
following data will be ignored.
2 Data type 1 0 to 1
×
0 = ABS, 1 = INC
1) - 11
D0MAX (±) nnnnnnY (±) nnnnnnL (±) nnnnnn
1 2 3 4
R (±) nnnnnn
H (±) nnnnnnA (±) nnnnnn
5 6 7
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Machine offset 1
command
2
× ×
Acknowledges as the set data
of machine offset 1.
When it is omitted, the
following data will be ignored.
2 X offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
3 Y offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
4 ZL offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
5 ZR offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
6 WH offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
7 WA offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-5
1) - 12
D0MBH (±) nnnnnnA (±) nnnnnn
1 2 3
T (±)nnnnnn
V (±) nnnnnnU (±) nnnnnn
4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Machine offset 2
command
2
× ×
Acknowledges as the set data
of machine offset 2.
When it is omitted, the
following data will be ignored.
2
θH offset
7
-999999 to
+999999
Max. digit includes ±.
1 / 100°
3
θA offset
7
-999999 to
+999999
Max. digit includes ±.
1 / 100°
4 T offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100°
5 V offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100°
6 U offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100°
=REMARKS=
If the data of 4 is out of range or it is not divisible by six, ‘A4E01’ is returned.
1) - 13
D0MTA (±) nnnnnnB (±) nnnnnnC (±) nnnnnnD (±) nnnnnn
1 2 3 4 5
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Rotary individual
offset command
2
× ×
Acknowledges as the set data
of rotary individual machine
offset.
When it is omitted, the
following data will be ignored.
2
Rotary chuck
1
7
-999999 to
+999999
Max. digit includes ±.
1 / 100°
3
Rotary chuck
2
7
-999999 to
+999999
Max. digit includes ±.
1 / 100°
4
Rotary chuck
3
7
-999999 to
+999999
Max. digit includes ±.
1 / 100°
5
Rotary chuck
4
7
-999999 to
+999999
Max. digit includes ±.
1 / 100°
=REMARKS=
If any data of 2 to 5 is not divisible by six, the column will become 0.