Host Computer System.pdf - 第58页

AVK3 HOST COMPUTER SYSTEM 3.2 Upl oading Part s Dat a D77HEC-53- 110-A0 3.2- 1 3.2. Uploading Parts Dat a D77HEC - 53-110-A 0 3.2. 1 Uploading Parts Data W ith A VK3, if host computer gives C1 command to AV K3, t he AVK3…

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
3.1 Uploading NC Data
D77HEC-53-010-A0
3.1-2
No. Data name
Max.
digits
Output range
Sup-
press
Vari-
able
Remarks
10
Insertion pitch
data
6 0 to 999999
± is for matching format.
Usually only + direction.
Max. digit includes ±.
1 / 100mm
11 Circuit No. 8
‘0’ to ‘9’
‘A’ to ‘Z
Fill with space if the digits are
not filled (8).
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE mode only.
If a program which does not exist in the memory is specified, ‘A4E00’ is returned.
Origin return block (GIT4 data) and final M0T0 block are added to output.
After receiving ‘A2’ from HOST, the processing ends.
Start of upload
Host computer
Sends out NC data.
AVK3
D 0 NC data
A 0
C1P
Control No.:
3 digits
Program name (Up
to 12 characters)
Sends out EOP data.
D 0
NC data
A 0
D 0 Block No.
Requests next data.
A 0
A 2
Requests next data.
Sends out NC data.
End of reception
End of transmission
AVK3
HOST COMPUTER SYSTEM
3.2 Uploading Parts Data
D77HEC-53-110-A0
3.2-1
3.2. Uploading Parts Data
D77HEC-53-110-A0
3.2.1 Uploading Parts Data
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal parts data and then can send leading block (one block) of parts data to AVK3.
Data details
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Program control
No.
15
‘0’ to ‘9’
‘A’ to ‘Z
Special character
Can be omitted.
(Excluding the first
character)
The program name given by the host computer and the name in the machine are compared. If the two
names as matched, parts data is returned.
1) -1
D0ZnnnP - BnnnLnnnCnSnnn
1 2 3 4 5 6
No. Data name
Max.
digits
Output range
Sup-
press
Vari-
able
Remarks
1 Z axis No. 4 001 to 122
×
Z122 is to be allotted to EOP
block.
Data is up to Z121.
2 Parts name 16
‘0’ to ‘9’
‘A’ to ‘Z
×
If NULL, 16 blank spaces are
output.
3 Part thickness 3 000 to 999
×
1 / 100 mm increments
4
Lead wire
diameter
3 000 to 999
×
1 / 100 mm increments
5 Chuck switching 1 0 to 3
×
0 = 26 mm, 1 = 52 mm,
2 = 26 mm + centering,
3 = 52 mm + centering
6 Spare feeder 3 000 to 120
×
Output range is up to Z120
since Z121 is allotted to
jumper.
1
STX
C 1
No. of
characters
ETX
Check sum
U
Program name
Up to 15 characters
(Can be omitted)
STX
D 0
No. of
characters
ETXCheck sum
Z x x x S x
1) -1
x x
AVK3
HOST COMPUTER SYSTEM
3.2 Uploading Parts Data
D77HEC-53-110-A0
3.2-2
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE mode only.
If a program which does not exist in the memory is specified, ‘A4E00’ is returned.
After receiving ‘A2’ from HOST, the processing ends.
Start of upload
Host computer
Sends out parts data.
AVK3
D 0 Parts data
A 0
C1U
Control No.:
3 digits
Program name (Up
to 12 characters)
D 0
Parts data
Requests next data.
A 0
Requests next data.
Sends out parts data.
Sends out EOP data.
A 0
D 0 Feeder No.
A 2
End of transmission
End of reception