AVK3 HOST COMPUTER SYSTEM 3.5 Upl oading P rogram Of f set D77HEC-53- 180-A0 3.5- 2 No. Data name Max. digit s Input r ange Sup- press Fi x Remarks 8 Ref erence hole 1 wi n do w si z e Y 3 0 to 479 ×   W indow s i ze Y…

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
3.5 Uploading Program Offset
D77HEC-53-180-A0
3.5-1
3.5. Uploading Program Offset
D77HEC-53-180-A0
3.5.1 Uploading Program Offset
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal program offset and then can send leading block (one block) of program offset to AVK3.
Data details
No. Data name
Max.
digits
Input range Omit Fix Remarks
1
Program control
No.
15
‘0’ to ‘9’
‘A’ to ‘Z
Special
character
Can be omitted.
(Excluding the first character)
The program name given by the host computer and the name in the machine are compared. If the two
names as matched, program offset is returned.
1) -1
D0X(±)nnnnnnY(±)nnnnnnFnnnAnB(±)nnnnnnC(±)nnnnnn
1 2 3 4 5 6
Dnnn
EnnnGnH(±)nnnnnnI(±)nnnnnnJnnnKnnn
7 8 9 10 11 12 13
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1 X program offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 /100 mm
2 Y program offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 /100 mm
3
Multiple origin
offset
3 0 to 120
×
Multiple origin
4
Reference hole 1
data
1 0 to 1
×
0 = Invalid, 1 = Valid
5
Reference hole 1
X coordinate
7
-999999 to
+999999
×
Max. digit includes ±.
1 /100 mm
6
Reference hole 1
Y coordinate
7
-999999 to
+999999
×
Max. digit includes ±.
1 /100 mm
7
Reference hole 1
window size X
3 0 to 511
×
Window size X
pix
1
STX
C 1
No. of
characters
ETX
Check sum
F
Program name
Up to 15 characters
(Can be omitted)
STX
D 0
No. of
characters
ETXCheck sum
X x x x F x
1) -1
x x
AVK3
HOST COMPUTER SYSTEM
3.5 Uploading Program Offset
D77HEC-53-180-A0
3.5-2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
8
Reference hole 1
window size Y
3 0 to 479
×
Window size Y
pix
9
Reference hole 2
data
1 0 to 1
×
0 = Invalid, 1 = Valid
10
Reference hole 2
X coordinate
7
-999999 to
+999999
×
Max. digit includes ±.
1 /100 mm
11
Reference hole 2
Y coordinate
7
-999999 to
+999999
×
Max. digit includes ±.
1 /100 mm
12
Reference hole 2
window size X
3 0 to 511
×
Window size X
pix
13
Reference hole 2
window size Y
3 0 to 479
×
Window size Y
pix
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE mode only.
If a program which does not exist in the memory is specified, ‘A4E00’ is returned.
After receiving ‘A2’ from HOST, the processing ends.
Start of upload
Host computer
Sends out program
offset.
AVK3
D 0 Program offset
A 0
C1F
Control No.:
3 digits
Program name (Up
to 12 characters)
D 0
Requests next data.
Sends out EOP data.
A 0
A 2
End of transmission
End of reception
AVK3
HOST COMPUTER SYSTEM
3.6 Uploading Production Information (Machine)
D77HEC-54-060-A0
3.6-1
3.6. Uploading Production Information (Machine)
D77HEC-54-060-A0
3.6.1 Uploading Production Information (Machine)
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal parts set number data and then can read the production information (machine) (using C1 command)
sent to the AVK3.
Data details
1) -1
C1MnnnP -
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Variable Remarks
1 Total designation 3 000 to 900
×
=000: Sub-total
(no clear after upload)
=900: Grand total
(clear after upload)
(900 is sub-total)
If program name is
designated, 3 digits
become fixed.
2 Program name 16
‘0’ to ‘9’
‘A’ to ‘Z
Special
character
If other than the valid
character, ‘A4E01’ is
returned.
If the name does not exist
in the memory, ‘A3’ is
returned.
1) -2
D0SDnnnn / nn / nn nn : nn
1 2 3 4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Collection start
date
2
×
Output command for the
production information
collection start date
2 Year (AD) 4 1991 to 2nnn
×
Corresponding to AD 2000
3 Month 2 01 to 12
×
4 Date 2 01 to 31
×
5 Hour 2 00 to 23
×
6 Minute 2 00 to 59
×
STX
C 1 M x
No. of
characters
ETX
1) -1
x x
Check sum
STX
D 0
No. of
characters
ETX
Check sum
1) -2 to 24