Host Computer System.pdf - 第78页
AVK3 HOST COMPUTER SYSTEM 3.6 Upl oading Producti on Inf ormation (M achine) D77HEC-54- 060-A0 3.6- 1 3.6. Uploading Production Infor mation ( Machine) D77HEC - 54-060-A 0 3.6. 1 Uploading P roducti on In for m ation (Ma…

AVK3
HOST COMPUTER SYSTEM
3.5 Uploading Program Offset
D77HEC-53-180-A0
3.5-2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
8
Reference hole 1
window size Y
3 0 to 479
×
Window size Y
pix
9
Reference hole 2
data
1 0 to 1
×
0 = Invalid, 1 = Valid
10
Reference hole 2
X coordinate
7
-999999 to
+999999
×
Max. digit includes ±.
1 /100 mm
11
Reference hole 2
Y coordinate
7
-999999 to
+999999
×
Max. digit includes ±.
1 /100 mm
12
Reference hole 2
window size X
3 0 to 511
×
Window size X
pix
13
Reference hole 2
window size Y
3 0 to 479
×
Window size Y
pix
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE mode only.
If a program which does not exist in the memory is specified, ‘A4E00’ is returned.
After receiving ‘A2’ from HOST, the processing ends.
Start of upload
Host computer
Sends out program
offset.
AVK3
D 0 Program offset
A 0
C1F
Control No.:
3 digits
Program name (Up
to 12 characters)
D 0
∗
Requests next data.
Sends out EOP data.
A 0
A 2
End of transmission
End of reception

AVK3
HOST COMPUTER SYSTEM
3.6 Uploading Production Information (Machine)
D77HEC-54-060-A0
3.6-1
3.6. Uploading Production Information (Machine)
D77HEC-54-060-A0
3.6.1 Uploading Production Information (Machine)
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal parts set number data and then can read the production information (machine) (using C1 command)
sent to the AVK3.
Data details
1) -1
C1MnnnP∗ - ∗
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Variable Remarks
1 Total designation 3 000 to 900
×
=000: Sub-total
(no clear after upload)
=900: Grand total
(clear after upload)
(≠900 is sub-total)
If program name is
designated, 3 digits
become fixed.
2 Program name 16
‘0’ to ‘9’
‘A’ to ‘Z’
Special
character
If other than the valid
character, ‘A4E01’ is
returned.
If the name does not exist
in the memory, ‘A3’ is
returned.
1) -2
D0SDnnnn / nn / nn nn : nn
1 2 3 4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Collection start
date
2
×
Output command for the
production information
collection start date
2 Year (AD) 4 1991 to 2nnn
×
Corresponding to AD 2000
3 Month 2 01 to 12
×
4 Date 2 01 to 31
×
5 Hour 2 00 to 23
×
6 Minute 2 00 to 59
×
STX
C 1 M x
No. of
characters
ETX
1) -1
x x
Check sum
STX
D 0
No. of
characters
ETX
Check sum
1) -2 to 24

AVK3
HOST COMPUTER SYSTEM
3.6 Uploading Production Information (Machine)
D77HEC-54-060-A0
3.6-2
1) -3
D0EDnnnn / nn / nn nn : nn
1 2 3 4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Collection end
date
2
×
Output command for the
production information
collection end date
2 Year (AD) 4 1991 to 2nnn
×
Corresponding to AD 2000
3 Month 2 01 to 12
×
4 Date 2 01 to 31
×
5 Time 2 00 to 23
×
6 Minute 2 00 to 59
×
1) -4
D0PCnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Production count
command
2
×
Output command for the
production count
2 Production count 9 0 to 999999999
×
1) -5
D0CCnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Production circuit
count command
2
×
Output command for the
production circuit count
2
Production circuit
count
9 0 to 999999999
×
1) -6
D0PTnnnnn : nn : nn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Power ON time
command
2
×
Output command for the
operation time
2 Operation time 11
0 : 0 : 0 to
99999 : 59 : 59
×
Output in the format of hour,
minute, second.