Host Computer System.pdf - 第83页
AVK3 HOST COMPUTER SYSTEM 3.6 Upl oadi ng Pr oduction I nform at i on (Mac h i ne) D77HEC-54- 060-A0 3.6- 6 1) -20 D0RE nnnnnnnn n 1 2 No. Data name Max. digit s Input r ange Sup- press Fi x Remarks 1 Reco v ery er ror…

AVK3
HOST COMPUTER SYSTEM
3.6 Uploading Production Information (Machine)
D77HEC-54-060-A0
3.6-5
1) -15
D0TRnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Total insertion
rate command
2
×
Output command for the total
insertion rate
2
Total insertion
rate
6 0 to 100000
×
1 / 1000% increments
1) -16
D0IRnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Insertion rate
command
2
×
Output command for the
insertion rate
2 Insertion rate 6 0 to 100000
×
1 / 1000% increments
1) -17
D0ORnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Operating rate
command
2
×
Output command for the
operating rate
2 Operating rate 6 0 to 100000
×
1 / 1000% increments
1) -18
D0ICnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Insertion count
command
2
×
Output command for the
Insertion count
2 Insertion count 9 0 to 999999999
×
1) -19
D0IEnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Insertion error
count command
2
×
Output command for the
Insertion error count
2
Insertion error
count
9 0 to 999999999
×

AVK3
HOST COMPUTER SYSTEM
3.6 Uploading Production Information (Machine)
D77HEC-54-060-A0
3.6-6
1) -20
D0REnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Recovery error
count command
2
×
Output command for the
recovery error count
2
Recovery error
count
9 0 to 999999999
×
1) -21
D0TEnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Total insertion
error count
command
2
×
Output command for the total
insertion error count
2
Total insertion
error count
9 0 to 999999999
×
1) -22
D0LEnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Transfer error
count command
2
×
Output command for the
transfer error count
2
Transfer error
count
9 0 to 999999999
×
1) -23
D0ESnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Error stop count
command
2
×
Output command for the error
stop count
2 Error stop count 9 0 to 999999999
×

AVK3
HOST COMPUTER SYSTEM
3.6 Uploading Production Information (Machine)
D77HEC-54-060-A0
3.6-7
1) -24
D0PEnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Parts exhaust
count command
2
×
Output command for the parts
exhaust count
2
Parts exhaust
count
9 0 to 999999999
×
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE mode only.
After receiving ‘A2’ from HOST, the processing ends.
If added to the name, the possible designated name will become to upload NC data command.
== As for the transfer data, see the ‘C1N command specification’.
Start of upload
Host computer
Sends out production
information (machine).
AVK3
D 0 Collection start date
A 0
D 0
Collection end date
Requests next data.
Sends out production
information (machine).
A 0
Requests next data.
A 0
D 0
∗
A 2
End of reception
End of transmission
C1M Total designation
A 0
D 0
Production information data
Requests next data.
Sends out production
information (machine).