AVK3 HOST COMPUTER SYSTEM 3.6 Upl oadi ng Pr oduction I nform at i on (Mac h i ne) D77HEC-54- 060-A0 3.6- 8

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
3.6 Uploading Production Information (Machine)
D77HEC-54-060-A0
3.6-7
1) -24
D0PEnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Parts exhaust
count command
2
×
Output command for the parts
exhaust count
2
Parts exhaust
count
9 0 to 999999999
×
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE mode only.
After receiving ‘A2’ from HOST, the processing ends.
If added to the name, the possible designated name will become to upload NC data command.
== As for the transfer data, see the ‘C1N command specification’.
Start of upload
Host computer
Sends out production
information (machine).
AVK3
D 0 Collection start date
A 0
D 0
Collection end date
Requests next data.
Sends out production
information (machine).
A 0
Requests next data.
A 0
D 0
A 2
End of reception
End of transmission
C1M Total designation
A 0
D 0
Production information data
Requests next data.
Sends out production
information (machine).
AVK3
HOST COMPUTER SYSTEM
3.6 Uploading Production Information (Machine)
D77HEC-54-060-A0
3.6-8
AVK3
HOST COMPUTER SYSTEM
3.7 Uploading Production Information (NC)
D77HEC-54-080-A0
3.7-1
3.7. Uploading Production Information (NC)
D77HEC-54-080-A0
3.7.1 Uploading Production Information (NC)
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal production information (NC) and then can read the production information (NC) (using C1 command)
sent to the AVK3.
Data details
1) -1
C1Nnnn
1
No. Data name
Max.
digits
Input range
Sup-
press
Variable Remarks
1 Total designation 3 000 to 900
×
=000: Sub-total
(no clear after upload)
=900: Grand total
(clear after upload)
(900 is sub-total)
AVK3 Host computer
1) -2
D0SDnnnn / nn / nn nn : nn
1 2 3 4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Variable Remarks
1
Collection start
date
2
×
Output command for the
production information
collection start date
2 Year (AD) 4 1991 to 2nnn
×
Corresponding to AD 2000
3 Month 2 01 to 12
×
4 Date 2 01 to 31
×
5 Time 2 00 to 23
×
6 Minute 2 00 to 59
×
STX
D 0
No. of
characters
ETX
Check sum