Host Computer System.pdf - 第86页
AVK3 HOST COMPUTER SYSTEM 3.7 Upl oading Producti on Inf ormation (NC) D77HEC-54- 080-A0 3.7- 1 3.7. Uploading Production Infor mation (NC) D77HEC - 54-080-A 0 3.7. 1 Uploading P roducti on In for m ation (NC) W ith A VK…

AVK3
HOST COMPUTER SYSTEM
3.6 Uploading Production Information (Machine)
D77HEC-54-060-A0
3.6-8

AVK3
HOST COMPUTER SYSTEM
3.7 Uploading Production Information (NC)
D77HEC-54-080-A0
3.7-1
3.7. Uploading Production Information (NC)
D77HEC-54-080-A0
3.7.1 Uploading Production Information (NC)
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal production information (NC) and then can read the production information (NC) (using C1 command)
sent to the AVK3.
Data details
1) -1
C1Nnnn
1
No. Data name
Max.
digits
Input range
Sup-
press
Variable Remarks
1 Total designation 3 000 to 900
×
=000: Sub-total
(no clear after upload)
=900: Grand total
(clear after upload)
(≠900 is sub-total)
AVK3 ⇒ Host computer
1) -2
D0SDnnnn / nn / nn nn : nn
1 2 3 4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Variable Remarks
1
Collection start
date
2
×
Output command for the
production information
collection start date
2 Year (AD) 4 1991 to 2nnn
×
Corresponding to AD 2000
3 Month 2 01 to 12
×
4 Date 2 01 to 31
×
5 Time 2 00 to 23
×
6 Minute 2 00 to 59
×
STX
D 0
No. of
characters
ETX
Check sum
1) -2 to 15

AVK3
HOST COMPUTER SYSTEM
3.7 Uploading Production Information (NC)
D77HEC-54-080-A0
3.7-2
1) -3
D0ED nnnn / nn / nn nn : nn
1 2 3 4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Collection end
date
2
×
Output command for the
production information
collection end date
2 Year (AD) 4 1991 to 2nnn
×
Corresponding to AD 2000
3 Month 2 01 to 12
×
4 Date 2 01 to 31
×
5 Time 2 00 to 23
×
6 Minute 2 00 to 59
×
1) -4
D0PPnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Planned
production count
command
2
×
Output command for the
planned production count
2
Planned
production count
9 0 to 999999999
×
1) -5
D0PCnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Production count
command
2
×
Output command for the
production count
2 Production count 9 0 to 999999999
×
1) -6
D0CCnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Production circuit
count command
2
×
Output command for the
production circuit count
2
Production circuit
count
9 0 to 999999999
×