STM1-S_SDV_Maintenance(Eng_Ver1).pdf - 第44页
W ee kly Inspe ction Chap ter 4 Multi -Func tional Placer ST M1-S M ain ten an ce Ha nd bo ok 4-1 Checking the Solenod V alve Measures Step 1. Ins er t th e CN0 40 noz zle into t he AN C. Step 2. Op era te th e mach ine …

STM1-S Maintenance Handbook
3-14
Chapter 3
Daily Inspection
Multi-Functional Placer
Inspection and replace the Detach nozzle pad
Daily Inspection
Step 3.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to "How to perform emergency stop" on page
1-2.
Step 4.
Opens the Detach cover and remove nozzle pad
manually.
Step 5.
If the nozzle pad is contaminated or torn, it must be
replaced.
Caution
Be careful not to cause any damage to a part that absorbs obsolete
tapes.
It is recommend to replace the nozzle pad every 6 months.

Weekly Inspection
Chapter 4
Multi-Functional Placer
STM1-S Maintenance Handbook
4-1
Checking the Solenod Valve
Measures
Step 1.
Insert the CN040 nozzle into the ANC.
Step 2.
Operate the machine to install the CN040 nozzle of the
ANC on the head.
Step 3.
Select the 'Diagnosis' menu of the MMI and select the
'Vacuum' submenu.
2
1
Checking the Solenod Valve
(Time required: 20min / No. W-1)
Chapter 4
Weekly Inspection

Weekly Inspection
Chapter 4
Multi-Functional Placer
STM1-S Maintenance Handbook
4-2
Checking the Solenod Valve
Weekly Inspection
Step 4.
Click the <Valve Check> button and select the Vacuum
ON/OFF count in the <Try> combo box of the 'Valve
Check' dialog box and then click the <Test> button.
3
5
4
Step 5.
If the check result shows that the solenoid valve has a
problem, contact our STS or local agent to replace the
corresponding solenoid valve.
For further details related to the solenoid valve check or for any
problems, refer to '14.4 Vacuum' of the Administrator's Guide.
Caution
Check the vacuum filter every week and replace it within at least 6
months to ensure the vacuum for part pickup is generated properly.
It is recommended that the solenoid valve, which is a consumable
product, is replaced every two years to ensure stable operation.