STM1-S_SDV_Maintenance(Eng_Ver1).pdf - 第47页

W ee kly Inspe ction Chap ter 4 Multi -Func tional Placer ST M1-S M ain ten an ce Ha nd bo ok 4-4 Checking and Replacing Head V acuum Filter W eekly Inspection Step 5. Rep lace t he vac uu m filte r Step 6 . Rele ase t h…

100%1 / 84
Weekly Inspection
Chapter 4
Multi-Functional Placer
STM1-S Maintenance Handbook
4-3
Checking and Replacing Head Vacuum Filter
Checking and Replacing Head Vacuum Filter
Measures
Step 1.
Move the X Frame to front by referring to "Forward
movement of the X-frame" on page 1-3.
Step 2.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to "How to perform emergency stop" on page
1-2.
Step 3.
Check for discoloration of the vacuum filter. (It is
recommended that you inspect for filter discoloration
monthly).
Step 4.
Saparate the coil tube from vacuum filter
Caution
Confirmation of Vacuum Filter inspection or after the exchange after
the Filter and the Tube and the assembled state.
(Time required: 30min / No. W-2)
Weekly Inspection
Chapter 4
Multi-Functional Placer
STM1-S Maintenance Handbook
4-4
Checking and Replacing Head Vacuum Filter
Weekly Inspection
Step 5.
Replace the vacuum filter
Step 6.
Release the emergency stop as described in "Releasing
'Emergency Stop' mode" on page 1-6 and perform the
operation again.
Caution
Check the vacuum filter every week and replace it within at least 6
months to ensure the vacuum for part pickup is generated properly.
Caution
It is recommended that the solenoid valve, which is a consumable
product, is replaced every two years to ensure stable operation.
Weekly Inspection
Chapter 4
Multi-Functional Placer
STM1-S Maintenance Handbook
4-5
Cleaning the conveyor chamber
Tool for Maintenance
cloth
Measures
Step 1.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to "How to perform emergency stop" on page
1-2.
Step 2.
Shut the main pneumatic pressure supplied to the
machine.
Step 3.
BELT TENSION SOL in IO status dialog box is changed
to Off.
Cleaning the conveyor chamber
(Time required: 15min / No. W-3)