STM1-S_SDV_Maintenance(Eng_Ver1).pdf - 第76页
Y e ar ly Inspe ction and Appe ndix Chap ter 6 Multi -Func tional Placer ST M1-S M ain ten an ce Ha nd bo ok 6-4 Replacing the Fuse Y ear ly Inspection and Appendix Step 5. Che ck t he po sitio n of th e fus e insid e th…

Yearly Inspection and Appendix
Chapter 6
Multi-Functional Placer
STM1-S Maintenance Handbook
6-3
Replacing the Fuse
Replacing the Fuse
Tool for Maintenance
(+) driver
Measures
Step 1.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to "How to perform emergency stop" on page
1-2.
Step 2.
Turn off the power supply to the machinet
For more details, refer to "How to turn off the power supply" on
page 1-1.
Step 3.
Separate Ring blower from the equipment.
(Time required: 15min / No. E-1)
Step 4.
Remove the rear cover of the machine using a crosshead
screwdriver.

Yearly Inspection and Appendix
Chapter 6
Multi-Functional Placer
STM1-S Maintenance Handbook
6-4
Replacing the Fuse
Yearly Inspection and Appendix
Step 5.
Check the position of the fuse inside the terminal block.
Step 6.
Remove the fuse and replace it with a new one.

Yearly Inspection and Appendix
Chapter 6
Multi-Functional Placer
STM1-S Maintenance Handbook
6-5
Replace the Ring blower fuse
Replace the Ring blower fuse
Tool for Maintenance
(+) driver, Fuse (200V / 2A)
Measures
Step 1.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to "How to perform emergency stop" on page
1-2.
Step 2.
Turn off the power supply to the machinet
For more details, refer to "How to turn off the power supply" on
page 1-1.
Step 3.
Use a (+) screwdriver to remove the Ring blower cover
at the back of the equipment.
(Time required: 15min / No. E-2)