00198124-02_JC_PM_WF4_TX_EN - 第21页

2 WF 4 TX-Series Maintenance Shut down and remove tables and exchange nozzles with JTF-ML 4 min 3 / 3 C A U T I O N !  R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c …

100%1 / 80
2 WF 4 TX-Series Maintenance Shut down and remove tables and exchange nozzles with JTF-ML 4 min 2 / 3
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part:
W2, W35
Consumables:
www.asm-smt.com
7 Remove all feeder tables 2. 8 Press stop button. 9 Open the cover 1.
10 Disconnect JTF-ML. 11 Press remove COT button. 12 Remove all feeder tables 1.
2 WF 4 TX-Series Maintenance Shut down and remove tables and exchange nozzles with JTF-ML 4 min 3 / 3
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part:
W2, W35
Consumables:
www.asm-smt.com
13 Switch off the machine when prompted. 14 Switch on the interior light. 15 Remove all ceramic nozzle magazines.
16 Return all maintained nozzle magazines.
www.asm-smt.com