19 WF 4 TX-Series Maintenance Calibrating the TH 14 min 5 / 9 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine Stat…

19 WF 4 TX-Series Maintenance Calibrating the TH 14 min 4 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T5
Wear Part: Consumables:
www.asm-smt.com
19 Click on check position and function DP
axis.
20 Click on zero correction data. 21 Click on arrow right to transfer Data from
eprom to head.
22 Click on right head and machine date. 23 Select the second head TH if required. 24 Repeat the steps 19 to 22.

19 WF 4 TX-Series Maintenance Calibrating the TH 14 min 5 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T5
Wear Part: Consumables:
www.asm-smt.com
25 Click on "calibration" icon. 26 Click on "automatic calibration" icon. 27 Click on "heads and cameras" icon and
de-select all others.
28 Click on "next" icon. 29 Select gantries for heads to be calibrated
and click "next" icon.
30 Click on "display setup" icon.

19 WF 4 TX-Series Maintenance Calibrating the TH 14 min 6 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T5
Wear Part: Consumables:
www.asm-smt.com
31 Click on "selected head" icon. 32 Click on "all nozzles" icon. 33 Click on "check configuration of the nozzle
changer" icon.
34 Check if 517 and 518 are in the nozzle
changer.
35 If the nozzles 517 and 518 are not in the
nozzle changer inform service.
36 Click on "set configuration of nozzles on
heads " icon.