19 WF 4 TX-Series Maintenance Calibrating the TH 14 min 9 / 9 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine Stat…

19 WF 4 TX-Series Maintenance Calibrating the TH 14 min 8 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T5
Wear Part: Consumables:
www.asm-smt.com
43 Press machine start if requested. 44 Calibration duration 5 mins. 45 Click on accept (1) and then on display
setup (2).
46 Click on all nozzles. 47 Click on return nozzles. 48 Select the second head TH if required.

19 WF 4 TX-Series Maintenance Calibrating the TH 14 min 9 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T5
Wear Part: Consumables:
www.asm-smt.com
49 Repeat the steps 46 to 47 if required. 50 Push stop button. 51 Open cover.
52 Remove the calibration tool. 53 Close cover. 54 Press start.

www.asm-smt.com