00193922-01 - 第90页

3 Technical data User Manual SIPLACE HF Series 3.2 Performance dat a for the mac hines Software Version S R.505.xx 05/2004 US E dition 90 3.2 Performanc e dat a for the mac hines T ypes of placemen t head SIPLAC E T win …

100%1 / 358
User Manual SIPLACE HF Series 3 Technical data
Software Version SR.505.xx 05/2004 US Edition 3.1 Description of the machine
89
3
Fig. 3.1 - 2 Placement principle using the Collect&Place method
3
The following options are available to extend the machine's functionality:
Additional component trolleys increase machine utilization since set-up times can be reduced
by carrying out preliminary set-up off the machine.
The dual conveyor also increases machine utilization by eliminating non-productive PCB trans-
port times.
Automatic nozzle changers speed up and optimize the nozzle configuration process.
PCB barcode scanners allow the production set-up to be changed over when triggered by a
new product.
Component barcode scanners optimize the set-up and refill checks.
Large and sensitive components can be supplied in trays in add-on matrix tray changers.
The productivity lift implements the concept of parallel placement, and thus improves the ratio
between productive and non-productive times.
3 Technical data User Manual SIPLACE HF Series
3.2 Performance data for the machines Software Version SR.505.xx 05/2004 US Edition
90
3.2 Performance data for the machines
Types of placement head SIPLACE TwinHead (TH)
6-segment Collect&Place head (C&P 6)
12-segment Collect&Place head (C&P 12)
Number of gantries HF: 2
HF/3: 3
Placement rate (benchmark)
HF
HF/3
Placement area 1 Placement area 2
C&P12 C&P12 28,000 comp./h
C&P12 C&P6 23,300 comp./h
C&P6 C&P6 18,600 comp./h
C&P12 TH 17,700 comp./h
C&P6 TH 13,000 comp./h
TH TH 7,400 comp./h
Placement area 1 Placement area 2
C&P12 / C&P12 C&P12 40,400 comp./h
C&P12 / C&P12 C&P6 35,700 comp./h
C&P12 / C&P12 TH 30,100 comp./h
C&P12 / C&P6 C&P6 29,600 comp./h
C&P12 / C&P6 TH 24,000 comp./h
C&P6 / C&P12 C&P6 29,600 comp./h
C&P6 / C&P12 TH 24,000 comp./h
C&P6 / C&P6 C&P6 27,600 comp./h
C&P6 / C&P6 TH 22,000 comp./h
Component range 0.6 x 0.3 mm² (0201) to 85 x 85 mm² / 125 x 10 mm²,
up to 200 x 125 mm² (with restrictions)
Component height C&P12: 6 mm
C&P6: 8.5 mm
TH: 25 mm (larger heights available upon request)
21.7 mm if a multicolor PCB vision camera (type 18) 21 is
installed
Placement accuracy C&P12: ± 60 µm (4 σ) standard, ± 55 µm (4 σ) DCA vision
camera
C&P6: ± 60 µm (4 σ) standard, ± 55 µm (4 σ) DCA vision
camera
TH: ± 35 µm (4 σ) standard, ± 30 µm (4 σ) component
camera,
stationary, P&P (type 20) 8x8 (flip chip camera)
Angular accuracy C&P12: ± 0.7° (4 σ)
C&P6: ± 0.3° (4 σ)
TH: ± 0.07° (4 σ)
Component feeding 4 component trolleys with tape roll holders and integral waste
containers
15 slots, 30 mm wide, per component trolley or
up to 2 matrix tray changers, rather than component trolleys
(HF/3: 1 MTC)
User Manual SIPLACE HF Series 3 Technical data
Software Version SR.505.xx 05/2004 US Edition 3.3 Ratings of the machines
91
3
3
3.3 Ratings of the machines
3
Feeder types Tapes, bulk cases, stick magazines, application-specific OEM
feeders, surftape feeders (8, 12, 16 mm), manual trays
Feeding capacity 180 tracks, width 8 mm (60 S feeders, 3 x 8 mm)
120 tracks, width 8 mm (60 S feeders, 2 x 8 mm)
60 tracks, width 12 or 16 mm (60 S feeders, 12/16 mm)
40 tracks, width 24 or 32 mm (40 S feeders, 24/32 mm)
28 tracks, width 44 mm (28 S feeders, 44 mm)
24 tracks, width 56 mm (24 S feeders, 56 mm)
20 tracks, width 72 mm (20 S feeders, 72 mm)
16 tracks, width 88 mm (16 S feeders, 88 mm)
PCB format
(LxW)
Single conveyor
50 x 50 mm² to 450 x 508 mm²
50 x 80 mm² to 610 x 508 mm² ("Long board" option)
Dual conveyor
50 x 50 mm² to 450 x 250 mm²
50 x 80 mm² to 610 x 250 mm² ("Long board" option)
Dual conveyor in Single conveyor mode
50 x 50 mm² to 450 x 450 mm²
50 x 80 mm² to 610 x 450 mm² ("Long board" option)
PCB thickness 0,3 - 4,5 mm (thicker PCBs available upon request)
Electrical ratings
Supply voltage 3 x 208 VAC ± 5 %; 50/60 Hz (for the U.S.A. version)
3 x 230 VAC ± 5 %; 50/60 Hz
3 x 380 VAC ± 5 %; 50/60 Hz
3 x 400 VAC ± 5 %; 50/60 Hz (Europe)
3 x 415 VAC ± 5 %; 50/60 Hz
Fuses 3 x 32 A (3 x 208 VAC)
3 x 32 A (3 x 230 VAC)
3 x 16 A (3 x 380 VAC)
3 x 16 A (3 x 400 VAC)
3 x 16 A (3 x 415 VAC)
Total connected load 11.1 kVA
Total power 6.5 kW
Rated power consumption of
the largest consumer
8.4 A (HF), 8.9 A (HF/3)
Power failure Max. 20 msec