00197551-01_MM_CPP-CP-Twin_Kunde_en - 第34页

Maintenance tasks for CPP Final Wo rk 3.5.11 Cleaning the Compone nt Sensor 34 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 3.6 3 . 6 F in a l W o r k Final Work Attaching the maintenance label Fitting…

100%1 / 92
Maintenance tasks for CPP
3.5.11 Cleaning the Component Sensor Performing Maintenance Tasks
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 33
3.5.11
3.5.11 Cleaning the Component Sensor
Cleaning the Component Sensor
CAUTION
Prism, cottonwool buds
Take care not to damage the component sensor prisms.
Make sure that you do not use the cottonwool buds soaked in oil from cleaning the sleeves.
Always use a new cottonwool bud!
Remove the protective cap from the component sen-
sor.
Clean the prisms of the component sensor with a cot-
tonwool bud soaked in ethanol.
Fit the protective cap onto the component sensor.
Maintenance tasks for CPP
Final Work 3.5.11 Cleaning the Component Sensor
34 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
3.6
3.6 Final Work
Final Work
Attaching the maintenance label
Fitting the front plate
Remove the front plate. For details, refer to the service manual.
Fitting the Placement Head
Fit the placement head back onto the gantry. Read the service manual for your machine first.
Remove the protective cap from the component sensor.
Switch the placement machine on at the main switch.
Perform a reference run.
If you have replaced the vacuum hoses on the DP drive, perform a vacuum check. If there are still
problems, have the hold circuit checked by the SIPLACE service team.
Calibrate the placement head, preferably using the FHE function. Read the service manual for your
machine first.
For SW703.02 and higher only: Reset the maintenance cycle counter for the corresponding assem-
blies.
Remove any label which may still be present from the
placement head.
Remove any adhesive residues and clean the area.
Attach the label and enter the date and, if required,
the meter count, depending on how you determine
your maintenance intervals.
Maintenance Tasks for C&P20/A/M/P Head
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 35
4
4 Maintenance Tasks for C&P20/A/M/P Head
Maintenance Tasks for C&P20/A/M/P Head
CAUTION
Do not get the heads mixed up!
Unless otherwise specified, all references made apply equally to the C&P20, C&P20 A,
C&P20 M and C&P20 P head.
Maintenance of the C&P20, C&P20 A, C&P20 M and C&P20 P heads is largely identical.
Any relevant differences will be mentioned explicitly.
The C&P20 M is only used with CA and Micron machines.
NOTICE
Example
All tasks are described using the example of a C&P20 A head. The procedure is the same for
other C&P20 variants. Any relevant differences will be mentioned explicitly.