Maintenance Tasks for C&P20/A/M/P Head Maintenance Manual SIPLACE Placement Heads CPP, C &P20, Twin 35 4 4 M a in t e n a n c e T a s k s f o r C & P 2 0 / A / M / P H e a d Maintenance Tasks for C&P20/A/…

Maintenance tasks for CPP
Final Work 3.5.11 Cleaning the Component Sensor
34 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
3.6
3.6 Final Work
Final Work
Attaching the maintenance label
Fitting the front plate
► Remove the front plate. For details, refer to the service manual.
Fitting the Placement Head
► Fit the placement head back onto the gantry. Read the service manual for your machine first.
► Remove the protective cap from the component sensor.
► Switch the placement machine on at the main switch.
► Perform a reference run.
► If you have replaced the vacuum hoses on the DP drive, perform a vacuum check. If there are still
problems, have the hold circuit checked by the SIPLACE service team.
► Calibrate the placement head, preferably using the FHE function. Read the service manual for your
machine first.
► For SW703.02 and higher only: Reset the maintenance cycle counter for the corresponding assem-
blies.
► Remove any label which may still be present from the
placement head.
► Remove any adhesive residues and clean the area.
► Attach the label and enter the date and, if required,
the meter count, depending on how you determine
your maintenance intervals.

Maintenance Tasks for C&P20/A/M/P Head
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 35
4
4 Maintenance Tasks for C&P20/A/M/P Head
Maintenance Tasks for C&P20/A/M/P Head
CAUTION
Do not get the heads mixed up!
Unless otherwise specified, all references made apply equally to the C&P20, C&P20 A,
C&P20 M and C&P20 P head.
► Maintenance of the C&P20, C&P20 A, C&P20 M and C&P20 P heads is largely identical.
Any relevant differences will be mentioned explicitly.
► The C&P20 M is only used with CA and Micron machines.
NOTICE
Example
All tasks are described using the example of a C&P20 A head. The procedure is the same for
other C&P20 variants. Any relevant differences will be mentioned explicitly.

Maintenance Tasks for C&P20/A/M/P Head
Differences Between C&P20, C&P20 A, C&P20 M and C&P20 P
36 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
4.1
4.1 Differences Between C&P20, C&P20 A, C&P20 M and C&P20 P
Differences Between C&P20, C&P20 A, C&P20 M and C&P20 P
CP20 Differenti ation
Differentiation of the C&P20 head variants
The C&P20/A/M and the C&P20 P head differ in many details. They are easily identified by the following
features:
1. The C&P20 P can be identified by the fan. This fan is not present on the C&P20/A/M heads.
2. The component sensor is flatter and wider on the C&P20 P than on the C&P20/A/M.
CAUTION
Do not confuse the different C&P20 head variants.
► Parts from the C&P20/A/M head can not usually be used for the C&P20 P head (and vice
versa)!